All installations must be provided with an isolator to cut off mains power supply 
and coarse current protection in the form of a fuse or MCB rated at 2-3 times 
the full load current as given on the pump plate.

Ÿ

Ensure that the power supply rating complies with the specification in these 
instructions.

Ÿ

Effective earthing must be provided according to local regulations.

Ÿ

Motors are protected against overloads by a thermal overload fitted in the 
motor windings.

5.  MAINTENANCE

The pump requires no routine maintenance and if correctly installed, should give 
long term trouble free service. However, the following should be noted:-

Ÿ

If pump performance drops check for debris in the impeller. If observed, flush 
with water to clean. If this action is insufficient, remove the suction cover and 
clean around the impeller.

Ÿ

Particularly check the pump seating location and clear any debris and silt that 
may have accumulated.

NOTE

Before  carrying  out  any  maintenance  ensure  the 
electrical supply is isolated.

NOTE

Before using the pump again, first “soak” it so that any 
possible dirt residues do not block the appliance.

Содержание DDW 400S

Страница 1: ...DDW DOMESTIC PUMPS Installation Operating Manual DDW400 750S DDW750 1000V...

Страница 2: ......

Страница 3: ...SPECIFICATIONS 1 1 2 WARNINGS AND SYMBOLS 3 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted 3 INSTALLATION 4 4 ELECTRICAL CONNECTIONS 4 5 MAINTENANCE 5 6 TROUBLE SHOOTING 6 7 WARRANT...

Страница 4: ...suitable for threaded or hose connection MOTORS Pumps are provided with integral non overloading induction motors designed for continuous operation A thermal cut out is provided in the motor winding t...

Страница 5: ...0 Max fluid temperature 35 C Max Operating Depth 7m Model Motor Dimensions mm Weight kg kW Outlet W DDW 400S DDW 750S 0 4 1 7 370 5 5 6 35 0 75 3 1 220 1 4 2 7 7 H Current A DDW 750V DDW 1000V Max Pa...

Страница 6: ...onds where they may be people using the water WARNING WARNING WARNING WARNING WARNING Repairs must be carried out only by a qualified electrician 2 WARNINGS AND SYMBOLS WARNING WARNING Do not use the...

Страница 7: ...may be straightened as desired The pump should not be suspended by its cable or delivery pipe It should either rest on a solid level base or be suspended by steel cable or chain The pump must be conne...

Страница 8: ...r windings 5 MAINTENANCE The pump requires no routine maintenance and if correctly installed should give long term trouble free service However the following should be noted If pump performance drops...

Страница 9: ...ed C l e a n s u c t i o n s e e maintenance section Delivery hose obstructed Check delivery hose rectify Pump runs with no flow Pump suction obstructed Check suction Delivery head too high Reduce del...

Страница 10: ...any warranty condition or liability implied by law the liability of Davis Shirtliff hereafter called the Company in respect of any defect or failure of equipment supplied is limited to making good by...

Страница 11: ......

Страница 12: ...INS181C 08 18 www davisandshirtliff com...

Отзывы: