Be sure device water and radiator valves are open. (Only radiator valve is 
open for ETT and ETM models.) 

Be sure that fuse andresidual current deviceare positioned as preventing 
electric transition.  

After you open enough insulation from head of electrical cables, place whole 
conductive part of cable by loosening connection terminal occurred at device 
and tightens cable holder screw as not looseness.  Be sure that cable fastens 
to its place as completely and solidly. Complete the connection by doing same 
process for other cables.  

 

               Be sure that cables were connected to correct places. 

 

               Loosen cable connections can be caused accidents.  Open residual 
current device the fuse.   After all indicating lights are seen within a few 
seconds, LCD display will be as in the following. 

 

 

 Keep press 

      2 seconds. If setting heating mode of the device was 

radiator modebefore it is OFF,after pump is operated about 1 min, device start 

to radiator heat and 

      sign is seen inside display. If the setting of the 

device was water heating before it is OFF, it stays in standby mode for hot 
water using. Warning beep is heard after every pressing knob process. For 
long time pressing knobs (for example 2-3 seconds),   before hearing warning 
beep, it does not mean pressing knob. 

 

 

Содержание Naviels UKDAX-10EDT

Страница 1: ...the device during the mounting and the usage of the device In case of an unauthorized mounting and maintenance the device will be void from warranty cover In addition to that our company will not be...

Страница 2: ...es that can be wet from external factors 8 Do not keep inflammable explosive or easy flammable materials and objects near the device 9 This INSTALLATION AND USER MANNUAL is supplemental part of the pr...

Страница 3: ...helper 18 In case of having smoked or burning smell originating from device make switch of the OFF position and contact with authorized service agency 19 Do not touch the device with wet hand or when...

Страница 4: ...must be place to suitable height 6 Ventilation of heated environment very long time increase the energy lost Short time ventilation must be made If it is needed to make long time ventilation closing...

Страница 5: ...3 CONFIGURATION OF THE DEVICE...

Страница 6: ...700 400 2 50 26 7 10 4 3 400 V 50 Hz Only Electrical Heating UKDAX 10ETT 10 700 400 2 50 23 8 7 UKDAX 12ETT 12 700 400 2 50 23 8 7 UKDAX 16ETT 16 700 400 2 50 23 8 7 UKDAX 18ETT 18 700 400 2 50 23 8 7...

Страница 7: ...Boiler installation must be done by authorized personnel 5 INSTALLATION OF BOILER...

Страница 8: ...Obey minimum distance that is anticipated for installation in order to reach the device for making regular maintenance 5 1 INSTALLATION CONDITIONS AND SAFETY WARNINGS...

Страница 9: ...sure reduce valve installed Device installation place must be far way from blockers obstruction parts and bulges during repairing and maintenance Electric connection of the device must be made with su...

Страница 10: ...r the device This process must be done byimplementing following instructions Be sure cold water inlet tap is open Open filling tap until water pressure indicator comes between 1 and 1 5 bar Close the...

Страница 11: ...ng valve connected to heating system For this connection with valve must be made from cold water installation to heating system This valve must placed near place to device because of it will be used f...

Страница 12: ...able which is determined according to cable length Electrical installation must have suitablespecification for cut off boiler power and residual current device that has ampere value and fuse separatel...

Страница 13: ...3 30 4 3 40 5 4 UKDAX 20ETT 20 3 30 4 3 40 5 4 UKDAX 24EDT 24 3 36 4 3 50 5 6 UKDAX 24ETT 24 3 36 4 3 40 5 6 UKDAX 30EDT 30 3 45 5 3 63 5 10 UKDAX 30ETT 30 3 45 5 3 50 5 10 UKDAX 36EDT 36 3 54 6 3 63...

Страница 14: ...he device can be follow from LCD panel Radiator operation indicator Days of week Time programming Can be made 3 pcs time programming Hour Capacity indicator Ready to Operation indicator 6 OPERATION AN...

Страница 15: ...icator Over Heating Indicator Over Heating Difference Value Pump operation indicator Freezing prevention indicator Room ThermostatConnection indicator Temperature indictor Use knobs located under LCD...

Страница 16: ...n be occur associated with intervention to device by unauthorized people Before operating the device suitability of all connections of mechanics and electrical must be controlled Heating system must h...

Страница 17: ...er cables Be sure that cables were connected to correct places Loosen cable connections can be caused accidents Open residual current device the fuse After all indicating lights are seen within a few...

Страница 18: ...ress button minute blinks minute setting between 0 and 60 is done by pressing or buttons 5 By pressing button or not pressing any button for a 10 second exit from setting menu by saving settings While...

Страница 19: ...summer mode setting can be made by or buttons while standby mode or operation mode 3 After the device is only taken to hot water heating mode summer mode setting can be made For this after it is press...

Страница 20: ...starting up by authorized service room thermostat connection will be activated from inside of device After room thermostat connection is done to the device it is needed to room thermostat bring into...

Страница 21: ...ange heating mode by user by consciously or by mistake For radiator heating modes if users want they can persuade operating of device maximum 55oC by changing into heating mode to ground heating mode...

Страница 22: ...with 3 different operation modes 1 Only Radiator Heating Mode Device only makes heating Although tap water is wanted to heat heating tap water cannot be occurred while heating mode is active 2 Only Ta...

Страница 23: ...uring program time and temperature difference can be made If the program is made or the program is active position device stays in heating mode for period of times that are not programmed With button...

Страница 24: ...program finish minute is determined 9 Press to button temperature indicator blinks With or chosen program operation temperature is determined 10 Press button is seen Temperature setting indicator bli...

Страница 25: ...ringing the water temperature to security level 35O C During Anti frost cycle is seen at LCD Anti Blockade Function Pump and 3 way valve inside the device start to operate once every 18 hrs If you do...

Страница 26: ...7 ELECTRICAL DIAGRAM...

Страница 27: ...between 1 2 bars 2 Call authorized service E1 Heating sensor damage Although you wait for a while if you have still seen the same code call the authorized service E3 Warning of water temperature is o...

Страница 28: ...tions 1 Connections must be made again 2 Sealing gasket must be renew 2 Sealing gasket is damaged X Keypad or PCB damage X Call the authorized service 1 Unproper cable using Turn off the device call t...