Weather Data Specifications
52
Solar Radiation
1 minute
1 W/m
2
0 to 1800 W/m
2
5% of full scale
Inside Temperature
(sensor in console)
1 minute
0.1
F; 0.1
C
+32
to +140
F;
0 to +60
C
0.5
F; 0.3
C
Outside
Temperature
***
10 seconds
0.1
F; 0.1
C
-40
to +150
F;
-40
to +65
C
0.5
F; 0.3
C
Extra Temperature
10 seconds
1
F; 1
C
-40
to +150
F
-40
to +65
C
0.5
F; 0.3
C
Heat Index
10 seconds
1
F; 1
C
-40
to +165
F;
-40
to +74
C
2
F (1
C)
Temp-Hum-Sun-
Wind index (THSW)
(Requires Solar
Radiation Sensor
10 seconds
1
F; 1
C
-90
to +165
F;
-68
to +74
C
4
F (2
C)
Time
1 min
24 hours
8 sec./mon.
Date
1 day
month/day
8 sec./mon.
UV Index
(requires UV Sensor)
1 minute
0.1 Index
0 to 16
5% of full scale
UV Dose
(requires UV Sensor)
1 minute
0.1 MED < 20,
1 MED > 20
0 to 199 MEDs
5%
Wind Direction
2.5 seconds
1
0 to 360
3
Compass Rose
2.5 seconds
22.5
16 compass pts
0.3 compass pt
Wind Speed
2.5 seconds
1 mph; 1 kt;
0.4 m/s; 1 km/h
0 to 200 mph;
0 to 173 kts
0 to 322 km/h,
0 to 809 m/s
greater of
2 mph/kts;
1 m/s; 3 km/h
or 5%
Wind Chill
10 seconds
1
F; 1
C
-110
to +135
F
-79
to +57
C
2
F;1
C
***
Outside temperature accuracy is based on the temperature sensor itself and not on the sensor
and the passive shielding together. The solar radiation induced error for standard ration shield:
+4
F (2
C) at solar noon; for fan aspirated radiation shield: +0.6
F (0.3
C) at solar noon (insolation
= 1040 W/m
2
, avg. wind speed
2 mph (1 m/s), reference: RM Young Model 43408 Fan-Aspirated
Radiation Shield).
Weather Data Specifications
Variable
Update
Interval
Resolution
Range
Nominal
Accuracy (+/-)
Содержание 6152