Installation
(for qualified installers only)
39
© Travis Industries
4140805
100-01384
Air Intake Installation (continued)
Before attaching the flex duct, make sure to
attach the intake damper wires to the damper
assembly. Then insert the wires into the flex
duct. Pull the wires through the duct, making
sure they do not catch any sharp edges.
Slide the flex duct into place.
NOTE
: In the pictured example, we have
crimped the intake damper. You may crimp this
or use the included slider plate or connector to
attach your flex duct.
Secure the flex duct to the intake damper with
two screws
DO NOT SCREW INTO THE TOP OF THE
INTAKE DAMPER – THIS MAY CAUSE
DAMAGE TO THE INTAKE DAMPER
ACTUATOR.
Use suitable tape to seal the duct joint.
Route the flex duct to the fireplace air intake.
Connect the wires from the air intake damper to
the wires from the fireplace.
NOTE
: The air intake wires may be shortened to
ease installation.