Installation
(for qualified installers only)
29
© Travis Industries
4140805
100-01384
Electrical Input Connection
Do not connect 110-120 VAC to the gas control valve or control system of this fireplace.
The electrical line to the grounded harness inside the fireplace must be installed by a qualified
installer and must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical connection. Turn the
breaker on only after all wiring is in place (power exhaust, on-off LED harness, etc.).
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
The electrical line must supply 120 Volts, 60 Hz, and 7 Amps (maximum draw).
Route the electrical connection through the cover plates and attach to the electrical input wires as
shown below.
Caution
:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
HINT
: Keep the cover plates disconnected until all wiring to the fireplace is attached. You may also
wish to leave the romex clamps loose until the cover plates are ready to be attached.
Power Exhaust Power Out
Electrical Input
Grommet
(remove to install wire)
Inner Cover Plate
Romex Clamp
Outer Cover Plate
1/4" Nutdriver