40 Installation
(for qualified installers only)
© Travis Industries
4140805
100-01384
Air Intake Dampers (for Hori. or Vert. Termination)
6” Dia. Intake Damper 98900078
8” Dia. Intake Damper 98900079
24V AC (orientation of wires does not matter)
Normally
Closed
Spring
Return
The intake damper wires are located inside the air intake on some fireplaces. Carefully fashion a
hole in the intake damper (or fireplace) and route the wires to the exterior of the duct. Make sure the
wires do not contact any sharp edges (use grommets if necessary). Seal the duct to ensure proper
airflow.
Route the intake damper wires from the fireplace to the damper. A 20’ extension is provided to
extend the wiring (if additional wiring is needed, use part 250-02295 or 18 gauge wire.
You will need to cut the quick-connects off the end of the wire harness. Attach the intake damper
wires to the upper and lower posts on the terminal block attached to the intake damper (see pictures
below -
orientation of the two wires does not matter
).