background image

37

8 Additional Features
8.1 Touch Pad Key Lock

The SP800 touch pad buttons can be locked to prevent unauthorised people from using the spa or 

modifying set up options. While the key lock is active button presses are ignored, however the LCD 

Display will temporarily show “KEYS LOCKED” to alert the user that the key lock is engaged.

8.2 Activating The Key Lock

To activate the key lock press and hold down the DOWN, SET and UP buttons together. While you are 

doing this, the LCD Display will show “HOLD KEYS TO ACTIVATE LOCK”. You will need to hold the 

buttons down for approximately three seconds before the lock is activated. At this point the touch pad 

will beep and show “KEYS LOCKED”.

8.3 Disabling The Key Lock

Once the key lock has been activated a button press sequence 

is required to disable it. Press each of the buttons listed in the 

unlock sequence, one at a time. The touch pad will beep and 

temporarily display “KEYS UNLOCKED” once the sequence is 

correctly entered. If you lose your place or incorrectly enter 

one of the buttons start over from the first step.
Unlock sequence: DOWN, SCROLL, DOWN, UP, SCROLL.
Note: If the controller is switched off while the key lock is active, 

the key lock will not be restored when power is reapplied.

8.4 Adjusting Touch Pad LCD Contrast

The touch pad LCD contrast/brightness can be manually adjusted if the display appears too dark or light.
To adjust the contrast, follow these steps:
1.  Press and hold down the LIGHT button. This will cycle the light intensity as usual, however you 

must keep the button held down before proceeding with the following steps. 

2.  With the LIGHT button held down, press the UP or DOWN buttons to darken or lighten the contrast 

as required. Hold down either button for automatic key press repeat. As you press the UP and 

DOWN buttons no key clicks or display changes will occur - this is normal.

3.  Once you have finished adjusting the contrast release the LIGHT button and the new setting will be saved.

Содержание Spa Power SP800

Страница 1: ...SP800 Models SP800 20 SP800 30 Q800AU 20 Q800 30 Single 3 phase models incorporating variable speed drive pumps and audio equipment controls User s Guide...

Страница 2: ...ed through a residual current device RCD having a rated residual operating current not exceeding 30 mA The system must be installed in such a way live parts are not accessible by a person in the pool...

Страница 3: ...Submenu Pg 30 7 9 1 Heat Control Pg 31 7 9 2 Changing heat control setting Pg 31 7 9 3 Heat Pump Pg 31 7 9 4 Changing the Heat Pump Setting if enabled Pg 32 7 9 5 High Heat Offset Pg 32 7 9 6 Changin...

Страница 4: ...y shows three quantities Current pool temperature Set Target pool temperature and clock weekday and time By default the current pool temperature is displayed on the numerical digits leaving the clock...

Страница 5: ...g If no water is being detected the LCD Display will also show WATER PRIMING PLEASE WAIT Auto Icon Water Icon Heater This LED shows when the heater is on The heater will turn on and off as required wh...

Страница 6: ...match the display on your touch pad to the column in the table below then refer to the specified section Option 1 PUMP LOW PUMP OFF PUMP AUTO SEE SECTIONS 2 1 1 page 4 3 1 page 6 Option 2 PUMP LOW PU...

Страница 7: ...sh to change pump mode PUMP AUTO PUMP ON PUMP OFF Pump 1B button Push to turn on off additional pump if fitted 2 1 4 Single Speed 24hr circulation pump fitted Pump 1A button Push to turn pump on off P...

Страница 8: ...on off and alter brightness Light mode button Push to change the light effects For more detailed information please see section 6 2 5 Setting The Temperature Push 1 Main Menu display appears see below...

Страница 9: ...Pump Off LCD displays PUMP OFF auto LED off button LEDs off This mode is used to turn pump 1 off for quiet relaxation The Hi Low speed button has no effect in this mode Push 3 Pump Auto LCD displays P...

Страница 10: ...Pump 1A 1B Single speed pumps no 24hr circulation pump fitted Three pushes of the Pump 1A button cycles the pump as follows Push 1 Pump On LCD displays PUMP ON button and Auto LEDs green Push 2 Pump O...

Страница 11: ...on pump fitted Five pushes of the Pump 1A button cycles the pump as follows Push 1 Pump Auto LCD displays PUMP AUTO button LED green Push 2 Pump On LCD displays PUMP ON button LED green Push 3 Pump Ra...

Страница 12: ...urrent speed setting While viewing this display you may press the UP and DOWN button to adjust the speed as required Hold down either button for automatic key press repeat This setting is saved and wi...

Страница 13: ...nutes 2 If the heater element is on running this outlet may cause the heater to load shed and switch off If this occurs the heater will come back on approximately 5 seconds after the pump is deselecte...

Страница 14: ...l speed or oscillating mode will automatically change the SPVSB to adjustable speed mode 4 If left on this accessory will automatically switch off after 25 minutes 5 If the heater element is on switch...

Страница 15: ...ntensity as required Hold down either button for automatic key press repeat This setting is saved and will be automatically restored next time you select the adjustable light intensity mode 6 2 Light...

Страница 16: ...aved individually and will be restored next time you select the given light effect mode Notes 1 The UP and DOWN buttons are shared with Light Level Light Mode SPVSB speed and the menu system When not...

Страница 17: ...17 7 Menu Structure...

Страница 18: ...Note that while viewing the menu title the LCD Display text above the SCROLL button shows ESC to indicate that the function of the SCROLL button is to escape from the menu The action taken by the SCRO...

Страница 19: ...of adjustment is 10 00 to 41 50 in steps of 0 25 degrees Celsius To change the setting press SCROLL while viewing the set temp menu item The current setting will flash indicating that the value may no...

Страница 20: ...wn either button for automatic key press repeat Press the SCROLL button once the desired time is reached This will set the timer running and the message TIMER STARTED STOP will be displayed While this...

Страница 21: ...ock mode 12hr or 24hr 4 Press the SCROLL button to confirm the current setting and move to the next field 5 Use the UP and DOWN buttons to adjust the selected field as required Hold down either button...

Страница 22: ...ch as pumps blower light etc The alarms are only active within one hour after the last button press on the touch pad If you have not used the spa in over an hour no sound will be produced 7 5 1 Config...

Страница 23: ...re a total of nine individual sleep times that can be programmed each of which can operate on one or more specified weekdays You may use as few or many of the sleep periods as you wish By default the...

Страница 24: ...ings to choose from Monday to Sunday and various combinations of each 5 Press the SCROLL button to confirm the current setting and move to the next field 6 Repeat steps four and five to carry on adjus...

Страница 25: ...he stop time is one minute before the start time If the two times are equal the sleep period will have no effect 3 It is normal for the spa to run for a long period after sleep to recover temperature...

Страница 26: ...er 4 Ozonator 5 Custom 1 6 Custom 2 7 Custom 3 8 Custom 4 9 Custom 5 7 7 2 Acknowledging A Maintenance Timer Once a timer is due you need to manually clear it it will not clear by itself Follow these...

Страница 27: ...e to the next field 7 Repeat steps 5 and 6 to set the number of weeks already elapsed Generally you will want to leave this field at 0 the start of the timed period 8 Press the SCROLL button once to r...

Страница 28: ...t MAIN menu then push UP button seven times 7 8 1 Key Clicks on off By default the touch pad will beep whenever a button is pressed however key clicks beeps may be turned on and off as desired using t...

Страница 29: ...etting if enabled 1 Select the MISC OPTIONS submenu from the main menu 2 Select the LED TIMEOUT menu item 3 Press the SCROLL button to begin LED TIMEOUT setting selection 4 Use the UP and DOWN buttons...

Страница 30: ...backlight will remain one user selectable fixed colour If desired the synchronising mirroring feature can be disabled and the touch pad backlight will remain on the fixed colour even when the pool li...

Страница 31: ...complex function of ambient conditions and the thermal characteristics of your spa set temp spa body insulation cover insulation heater rating etc It is recommended that you start with the default no...

Страница 32: ...ing is used it is red when the heater is on high and orange when on low The high heat offset setting allows you to configure how far below the set point the water temperature must fall before the high...

Страница 33: ...mp will come on no more than once an hour to ensure filtration times are met similarly a setting of 4 hours indicates that a filtration run will occur once every 4 hours 1 Select the ADV OPTIONS subme...

Страница 34: ...leep times but also settings such as preferred light mode light effect speeds and blower speed will be restored to their factory defaults Only use this option if you are absolutely sure it is necessar...

Страница 35: ...IN MENU ESC STEREO CONTROLS SOURCE next OFF STEREO CONTROLS SOURCE next OFF STEREO VOLUME next TRACK TUNE SEEK next FOLDER PREsetCH next STEREO CONTROLS PAUSE next MUTE STEREO CONTROLS PAUSE next MUTE...

Страница 36: ...ancel press again Push DOWN to access the PAUSE item Push DOWN MAIN MENU ESC STEREO CONTROLS SOURCE next OFF STEREO CONTROLS SOURCE next OFF STEREO VOLUME next TRACK TUNE SEEK next FOLDER PREsetCH nex...

Страница 37: ...d will beep and temporarily display KEYS UNLOCKED once the sequence is correctly entered If you lose your place or incorrectly enter one of the buttons start over from the first step Unlock sequence D...

Страница 38: ...everse the display press the UP and DOWN buttons simultaneously To restore the display press the UP and DOWN buttons again 8 6 Language Selection The SP800 spa controller can be set to display English...

Страница 39: ...to start over With any Error 3 8 spa operation will stop and not continue until the controller is reset The controller can only be reset by pushing the Light Level Light Effect Mode Pump 1Aand SPVSB b...

Страница 40: ...Light Effect Mode Pump 1A and Pump 2A buttons simultaneously If there is still a problem then contact your spa pool supplier Error 6 THERMAL CUT OUT Thermal Cut Out Tripped This error indicates that t...

Страница 41: ...s not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure they do not play with the appliance Warnings Warning 1 TEMP SENSOR FAILURE...

Страница 42: ...tat pockets High pH will cause scale formation and cloudy water Total Alkalinity This is a measure of how resistant your spa water is to change of pH A low TA 0 80 ppm will allow the pH to fluctuate r...

Страница 43: ......

Страница 44: ...d by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none o...

Отзывы: