6

PM200BT electrical specifications

Flow

Setting

Best efficiency point

Maximum

Flow

Head

Input power 

(P

1

)

Output power 

(P

2

)

Flow

Head

Input power 

(P

1

)

Output power 

(P

2

)

L/min

m³/h

m

hp

W

hp

W

L/min

m³/h

m

hp

W

hp

W

Dial 1

85

5.1

3

0.16

 123 

0.11

 86 

155

9.3

4

0.17

 128 

0.12

 90 

Dial 2

100

6.0

4

0.26

 193 

0.18

 135 

187

11.2

6

0.28

 207 

0.19

 145 

Dial 3

125

7.5

5

0.38

 283 

0.26

 198 

217

13.0

7

0.39

 293 

0.27

 205 

Dial 4

143

8.6

6

0.51

 383 

0.36

 268 

246

14.8

10

0.53

 398 

0.37

 279 

Dial 5

155

9.3

8

0.66

 495 

0.46

 347 

272

16.3

12

0.70

 524 

0.49

 367 

Dial 6

160

9.6

10

0.82

 612 

0.57

 428 

297

17.8

14

0.87

 655 

0.61

 459 

Dial 7

183

11.0

11

1.02

 766 

0.71

 536 

322

19.3

16

1.08

 807 

0.75

 565 

Dial 8

195

11.7

12

1.17

 880 

0.82

 616 

339

20.3

17

1.25

 936 

0.87

 655 

Dial 9

207

12.4

13

1.36

 1,017  0.95

 712 

358

21.5

19

1.44

 1,078 

1.01

 755 

Dial 10

210

12.6

14

1.45

 1,090  1.02

 763 

363

21.8

20

1.48

 1,111 

1.04

 778 

PM400BT hydraulic performance

10 

15 

20 

25 

50 

100 

150 

200 

250 

300 

350 

400 

450 

To

tal Head ( m ) 

Dial position No. 10 

Dial position No. 9 

Dial position No. 8 

Dial position No. 7 

Dial position No. 6 

Dial position No. 5 

Dial position No. 4 

Dial position No. 3 

Dial position No. 2 

Dial position No. 1 

Flow ( lpm ) 

Flow ( m

3

/h ) 

0

0

3

6

9

12

15

18

21

24

27

PM400BT electrical specifications

Flow

Setting

Best efficiency point

Maximum

Flow

Head

Input power 

(P

1

)

Output power 

(P

2

)

Flow

Head

Input power 

(P

1

)

Output power 

(P

2

)

L/min

m³/h

m

hp

W

hp

W

L/min

m³/h

m

hp

W

hp

W

Dial 1

98

5.9

2

0.16

 117 

0.11

 82 

160

9.6

3

0.17

 126 

0.12

 88 

Dial 2

112

6.7

4

0.26

 192 

0.18

 134 

197

11.8

5

0.28

 210 

0.20

 147 

Dial 3

140

8.4

5

0.42

 316 

0.29

 221 

240

14.4

8

0.46

 347 

0.32

 243 

Dial 4

165

9.9

7

0.62

 468 

0.44

 328 

282

16.9

10

0.70

 522 

0.49

 366 

Dial 5

190

11.4

9

0.88

 660 

0.62

 462 

322

19.3

13

0.97

 728 

0.68

 509 

Dial 6

200

12.0

11

1.09

 817 

0.76

 572 

349

21.0

15

1.22

 912 

0.85

 638 

Dial 7

225

13.5

13

1.44

 1,080  1.01

 756 

388

23.3

19

1.61

 1,211 

1.13

 848 

Dial 8

240

14.4

15

1.77

 1,330  1.24

 931 

414

24.9

22

1.97

 1,478  1.38

 1,034 

Dial 9

250

15.0

16

1.99

 1,495 

1.40

 1,047 

420

25.2

24

2.18

 1,636  1.53

 1,145 

Dial 10

260

15.6

16

2.16

 1,620 

1.51

 1,134 

420

25.2

26

2.19

 1,639  1.53

 1,147 

Содержание ProMaster PM200BT

Страница 1: ...ation and Operating Instructions 50 60Hz Please refer to the Davey website in your region as per back page of this document for any product information updates ProMaster Please pass these instructions on to the operator of this equipment PM200BT PM400BT ...

Страница 2: ...0 Full variable frequency drive with user friendly selectable speed dial 10 Large 4 5 litre lint pot 10 Patented water cooled design for smooth and super quiet operation 10 PM400BT constant flow speed compensation 10 PM400BT weatherproof RJ45 Communication Port see section 7 for connection details 10 6 BLUETOOTH FUNCTIONALITY 11 Bluetooth App Set Up 11 Pairing a device to the pump 11 External Time...

Страница 3: ...rds All electrical installations must be carried out by a qualified electrician Davey recommends that all installations are fitted with earth leakage or residual current protection devices Rated residual operating current not exceeding 30mA WARNING Ensure that an electrical isolation switch is located with easy access so that the pump can be switched off in an emergency F NFC C 15 100 GB BS7671 19...

Страница 4: ...olation valves used where equipment is located below pool water level should also be installed no closer than 250mm from inlet barrel union This will assist laminar flow 250mm ELBOW Figure 1 1 Figure 1 2 152mm MINIMUM 76mm MINIMUM Suction line 40 50mm Return to Pool 40 50mm Suction line 40 50mm Return to Pool 40 50mm The discharge piping from the ProMaster outlet should be connected to the inlet c...

Страница 5: ...0 15 20 25 0 50 100 150 200 250 300 350 400 Total Head m ProMaster PM200SV Performance Dial position No 10 Dial position No 9 Dial position No 8 Dial position No 7 Dial position No 6 Dial position No 5 Dial position No 4 Dial position No 3 Dial position No 2 Dial position No 1 Flow lpm Flow m3 h 0 0 3 6 9 12 15 18 21 24 ...

Страница 6: ...400 450 Total Head m Dial position No 10 Dial position No 9 Dial position No 8 Dial position No 7 Dial position No 6 Dial position No 5 Dial position No 4 Dial position No 3 Dial position No 2 Dial position No 1 Flow lpm Flow m3 h 0 0 3 6 9 12 15 18 21 24 27 PM400BT electrical specifications Flow Setting Best efficiency point Maximum Flow Head Input power P1 Output power P2 Flow Head Input power P...

Страница 7: ...tion pool cleaner in floor cleaning system pool heaters A backwash setting on the pump can be selected to backwash a media filter What to expect with the ProMaster energy efficient operation on your pool If your ProMaster pump is replacing a traditional AC motor pump you may will need to run it longer than your old fixed speed pump This is NORMAL and you will save energy when using lower speed set...

Страница 8: ...es for recommended pump operating hours Typical residential pool turnover rate shall be a single turnover of the full volume of the pool water within the daily period that the pump would normally be operating The table below provides a guide only to the running times of your pump while in filtration mode in order to achieve the minimum turnover rate ProMaster PM200BT Pool size Litres Speed Setting...

Страница 9: ...at it seals on the large rubber o ring Firm hand tightness only is required The o ring thread can be lubricated with Hydra Slip or equivalent products Failure to undertake regular maintenance may cause damage not covered by warranty Routine maintenance To maximise the life of the ProMaster and for personal safety use this checklist once a week Ensure pump is off before starting Make sure that any ...

Страница 10: ...ning Patented water cooled design for smooth and super quiet operation The ProMaster has a water cooled membrane and jacket around the motor which helps to keep the pump cool during operation Waste heat off the motor is transferred into the pool water helping to reduce pool heating energy costs PM400BT constant flow speed compensation As the pool filter becomes dirty pressure builds up With a typi...

Страница 11: ...sking if you are using an external timer or chlorinator to control the ProMaster Please select yes no This is a safety function that helps ensure the chlorinator only runs when the pump is working Note App screenshots are for demonstration purposes only Actual screens may vary Manual or scheduled mode Two modes are available depending on whether you wish to manually operate the ProMaster or altern...

Страница 12: ...n the schedule selected The row at the bottom of the screen indicates a summary of where the schedule is by day and by hour This summary screen can easily be altered by swiping up or down the columns above Note If using a chlorinator you must ensure that the on times on the pump correspond to the on times on the chlorinator The pump will remain in the last used mode whether that be manual mode or ...

Страница 13: ... with your phone This procedure is in place so that the pump cannot accidentally be reset Pump fault finding In the instance that there is a fault the following screen will appear with text description below the fault indicating how to remedy ProMaster BT Fault title Fault description Pump fault overcurrent Check that the motor can rotate freely Unplug for 1 minute and plug back in to reset If pro...

Страница 14: ...ypad communication error or Pump fault fieldbus communication error or Pump fault fieldbus interface error Unplug for 1 minute and plug back in to reset If problem persists call Davey or an authorised repair agent 7 ADVANCED SETUP OF PM400BT External AUX connections overview Your ProMaster PM400BT has an RJ45 style waterproof socket to allow for external control of motor speed and other functional...

Страница 15: ... dial speed setting To set one of these inputs either Connect an isolated 24V supply between DC ground and the digital input pin Connect the switched contacts of a relay between the 24V pin and the digital input The fixed speeds as a proportion of full speed are Input 1 Pin 7 Input 2 Pin 6 Input 3 Pin 3 Output Speed 0 0 0 Dial 0 0 24V 33 0 24V 0 50 0 24V 24V Backwash 24V 0 0 100 24V 0 24V 67 24V 2...

Страница 16: ...ft part of the diagram above Analogue control inputs Speed control can also be achieved by connecting a 0 10V DC signal at the input on pin 4 ground at pin 5 As soon as a signal above 0V is registered this input will take priority over dial settings For example 10V DC will change pump speed pump to 100 5V DC will change pump speed to 50 etc Pin4 Blue Pin5 Blue White 0 10 V DC Signal Output of cont...

Страница 17: ...ct the pool cleaner hose firmly into the skimmer plate or dedicated wall suction Select the speed setting that enables best performance from your suction pool cleaner Speed 3 to 7 should be ample for most cleaners however if the cleaner requires better performance select speeds 7 to 10 The cleaner should only be connected for as long as is required to clean the surface of your pool When cleaning i...

Страница 18: ...main power supply switch Automatic overload is tripped The pump has an in built thermal overload which will reset automatically after the motor has cooled following an overheating period Determine the cause of the overload tripping and rectify Reset the pump by switching the power OFF for 30 seconds Blockage is preventing the pump from rotating 12 REMOVAL OF THE PROMASTER FROM PIPEWORK Should it b...

Страница 19: ...d electrical equipment is in good condition Damaged wiring must be repaired or replaced by a qualified electrician as soon as damage is discovered h Check water balance and sanitiser levels at your local pool shop POWER CONNECTIONS AND WIRING MUST BE CARRIED OUT BY AN AUTHORISED ELECTRICIAN DANGER Hazardous suction Do not block water entry into filtration system with any part of your body as the p...

Страница 20: ...art or component is not available Goods presented for repair may be replaced by refurbished goods of the same type rather than being repaired Warranty claims 1 If a fault covered by the warranty occurs Davey suggests in the first instance that you contact the Davey Dealer from whom you purchased the product Alternatively you can phone the Davey Customer Service line on 1300 367 866 in Australia or...

Отзывы: