background image

• Page 2 •

Eco

Salt

Salt Water Pool Systems

Congratulations!  You  are  now  the  proud  owner  of  the  renowned  EcoSalt

  Salt  Water 

Chlorinator.  Please  read  all  information  in  this  manual  carefully  before  installing  or 
operating your EcoSalt

 Salt Water Pool Chlorinator

INDEX

Page 2 

Packing List

Page 3 

Important Notice

Page 4 

Installation Instructions

Page 5 

Pre-Start up Procedure

Page 5 

Operation of your EcoSalt

 System

Page 7 

EcoSalt

 Special Features

Page 8 

Automatic Time Clock Operation

Page 10 

Maintenance of Power Supply and Electrolytic Cell

Page 11 

Day to Day Operation

Page 12 

Chlorine Production

Page 13 

General Information: Recommended Pool Water Chemistry

Page 14 

Trouble Shooting 

Page 15 

Mounting Template

Page 16 

Guarantee & Terms & Conditions

PACKING LIST - EcoSalt

Included with your EcoSalt

 System are the following items, please check the contents of the box carefully 

prior to attempting to install the system:    

          

1. Power Supply / Controller

2. Electrolytic Cell

3. 2 x 50mm Barrel Unions

4. 2 x 50x40 PVC Reducing Bush

5. Mounting Kit & Spare Fuse

 

Содержание Monarch EcoSalt 13

Страница 1: ...au EcoSalt SaltWater Pool Systems INSTALLATION OPERATING INSTRUCTIONS Includes Guarantee Terms Conditions Model BMSC Series IMPORTANT PLEASE READTHIS DOCUMENT CAREFULLY Please pass these instructions...

Страница 2: ...oSalt Special Features Page 8 Automatic Time Clock Operation Page 10 Maintenance of Power Supply and Electrolytic Cell Page 11 Day to Day Operation Page 12 Chlorine Production Page 13 General Informat...

Страница 3: ...of the electrolytic cell is recommended The Cell is the clear plastic housing containing the removable cell head During the chlorination process a white powdery Calcium scale may naturally build up o...

Страница 4: ...ation Simply cut out Template at bottom of page 15 for location of drill entry points Use a 7mm masonry drill bit when fitting Power Supply to a brick or concrete wall When mounting to a post drill pi...

Страница 5: ...d into deepest end of pool and allow vacuum to continue for a further 2 or 3 hours Salt should now be completely mixed Never add salt directly into skimmer box CHLORINE For a new pool installation tha...

Страница 6: ...her A or B whichever is on or brightest The RED Operation LED will indicate a number of different possible problem situations Possible Problem Action Salt Level Below Minimum Add Salt Cell is Calcifie...

Страница 7: ...D whose primary function includes Low Salinity Indicator As the salt level in the pool decreases the wear on the Cell increases Although salt is not consumed in the EcoSalt process it is lost through...

Страница 8: ...et the current time on the digital clock Select the Set Clock position on the selector switch to enable the time of day to be input A number 1 will appear at the left of the screen a The display will...

Страница 9: ...umber 4 will appear on the left of the screen This time is factory pre set to 11pm Proceed as per a in the Set Clock instruction to change time To disable this timer see notes on selector switch 4 Aut...

Страница 10: ...w times each year One exception is the use of bore water or ground water in which case cleaning may always need to be as frequent as once a week The life of Eco Salt electrolytic cells vary substantia...

Страница 11: ...ol shop to ensure that you do not add too much 2 pH AND TOTAL ALKALINITY A correct pH level must be maintained to prevent problems such as black spot staining cloudy water etc An incorrect pH level ca...

Страница 12: ...borne dust require different running times in which case seek advice from your pool shop During Winter approximately 4 to 6 hours a day should provide enough chlorine Without sufficient filtration ch...

Страница 13: ...or Cell ppm An abbreviation for Parts Per Million the accepted measurement of chemical concentration in swimming pool water I ppm l mg L The appropriate chlorinator size for your pool is dependent on...

Страница 14: ...etting 6 Chlorinator fuse blown 7 Dirty Cell 8 Filter needs back washing 9 Gas Sensor not connected 10 Insufficient water flow through cell 11 Running times incorrect 12 Main house fuse blown 13 Pump...

Страница 15: ...Page 15...

Страница 16: ...izing in accordance with Davey s recommendations 5 This guarantee is subject to due compliance by the original purchaser with all directions and conditions set out in the Installation and Operating In...