IMPORTANT NOTICE:

FACTORS THAT WILL IMPROVE THE PERFORMANCE & LIFE OF YOUR SALT WATER CHLORINATOR

PLEASE READ THIS BEFORE OPERATING YOUR CHLORINATOR

POOL BUILDERS:

 Please cover this information with your customer during the new pool “Hand over 

Session”

Salt Water Chlorinators are a valuable piece of pool sanitising equipment and must be cared for to get the 
best performance and life span from it.

There are 

THREE

 main factors that will damage your chlorinator and reduce the life of the product. Please  

monitor the following factors in accordance with your installation & operating instructions.

  1. MAINTAIN RECOMMENDED SALT LEVELS:

 

RECOMMENDED OPERATING RANGE: 4500-6000ppm 

 

NOTE: ABOVE GROUND POOL MODELS ONLY: 2500ppm

•  Run chlorinator at the Salt Levels stated within this document and on the product to ensure 
 

optimum sanitiser output and cell life.

•  Operating this device at low salt levels will damage the cell and reduce its life.
•  The control panel displays a red LED indicator warnings when the salt levels are low.
•  If no action is taken to rectify the salt levels, damage to the cell may result which will not be covered 
 

under warranty.

 

  2. MONITOR & MAINTAIN YOUR CHLORINATOR CELL:

 

EcoSalt™  has a “Reverse Polarity” cell.

•  To keep your salt water chlorinator in the best possible condition, regular monitoring of the electrolytic 
 

cell is recommended. The ‘Cell’ is the clear plastic housing containing the removable cell head.

•  During the chlorination process a white powdery Calcium scale may naturally build up on the titanium 
 

plates in the cell.  Monitor the cell to prevent excessive scale build up. Excessive scale build up will cause 

 

damage to your cell, and dramatically reduce its efficiency and lifespan.

•  Reverse Polarity models have low maintenance cells that minimise scale build up.
•  The control panel displays a red LED indicator warning when the cell requires cleaning.
•  If Calcium scale builds up please clean the cell, following the cleaning instructions provided on page 11.
• 

NEVER

:

 Use concentrated acid to clean your cell.

• 

NEVER

:

 Leave cell in cleaning solution for extended periods of time

• 

NEVER

:

 Use metal implements, scourers or brushes to clean your cell

 

    3. BALANCED POOL WATER CHEMISTRY:

•  Salt levels MUST be maintained at 4500-6000ppm for optimum performance and lifespan 
 

(NOTE: Above ground pool models: 2500ppm)

•  Calcium Hardness levels 

MUST

 be kept to ideal ranges of 

200-275ppm

 (for Concrete and Tiled Pools) 

 

and 

100-225ppm

 (for other surfaces) to prevent excessive scale build up and damage to equipment

•  pH levels 

MUST

 be kept to ideal levels to prevent damage to equipment and pool surfaces and to obtain 

 

optimum sanitiser effectiveness.

•  Total Alkalinity and Stabiliser levels must also be kept in an ideal range. 

Note: Please refer to the RECOMMENDED POOL WATER CHEMISTRY chart on page 13 for more 
information.

Содержание Monarch EcoSalt 13

Страница 1: ...au EcoSalt SaltWater Pool Systems INSTALLATION OPERATING INSTRUCTIONS Includes Guarantee Terms Conditions Model BMSC Series IMPORTANT PLEASE READTHIS DOCUMENT CAREFULLY Please pass these instructions...

Страница 2: ...oSalt Special Features Page 8 Automatic Time Clock Operation Page 10 Maintenance of Power Supply and Electrolytic Cell Page 11 Day to Day Operation Page 12 Chlorine Production Page 13 General Informat...

Страница 3: ...of the electrolytic cell is recommended The Cell is the clear plastic housing containing the removable cell head During the chlorination process a white powdery Calcium scale may naturally build up o...

Страница 4: ...ation Simply cut out Template at bottom of page 15 for location of drill entry points Use a 7mm masonry drill bit when fitting Power Supply to a brick or concrete wall When mounting to a post drill pi...

Страница 5: ...d into deepest end of pool and allow vacuum to continue for a further 2 or 3 hours Salt should now be completely mixed Never add salt directly into skimmer box CHLORINE For a new pool installation tha...

Страница 6: ...her A or B whichever is on or brightest The RED Operation LED will indicate a number of different possible problem situations Possible Problem Action Salt Level Below Minimum Add Salt Cell is Calcifie...

Страница 7: ...D whose primary function includes Low Salinity Indicator As the salt level in the pool decreases the wear on the Cell increases Although salt is not consumed in the EcoSalt process it is lost through...

Страница 8: ...et the current time on the digital clock Select the Set Clock position on the selector switch to enable the time of day to be input A number 1 will appear at the left of the screen a The display will...

Страница 9: ...umber 4 will appear on the left of the screen This time is factory pre set to 11pm Proceed as per a in the Set Clock instruction to change time To disable this timer see notes on selector switch 4 Aut...

Страница 10: ...w times each year One exception is the use of bore water or ground water in which case cleaning may always need to be as frequent as once a week The life of Eco Salt electrolytic cells vary substantia...

Страница 11: ...ol shop to ensure that you do not add too much 2 pH AND TOTAL ALKALINITY A correct pH level must be maintained to prevent problems such as black spot staining cloudy water etc An incorrect pH level ca...

Страница 12: ...borne dust require different running times in which case seek advice from your pool shop During Winter approximately 4 to 6 hours a day should provide enough chlorine Without sufficient filtration ch...

Страница 13: ...or Cell ppm An abbreviation for Parts Per Million the accepted measurement of chemical concentration in swimming pool water I ppm l mg L The appropriate chlorinator size for your pool is dependent on...

Страница 14: ...etting 6 Chlorinator fuse blown 7 Dirty Cell 8 Filter needs back washing 9 Gas Sensor not connected 10 Insufficient water flow through cell 11 Running times incorrect 12 Main house fuse blown 13 Pump...

Страница 15: ...Page 15...

Страница 16: ...izing in accordance with Davey s recommendations 5 This guarantee is subject to due compliance by the original purchaser with all directions and conditions set out in the Installation and Operating In...

Отзывы: