Quick Reference

2.1.1 Two Speed (no 24hr circulation pump)

Section 2.0

2.1.2 Two Speed (24hr circulation pump fitted)

Pump 1B button: Push to change pump speed (LOW, HIGH)

2.1.3 Single Speed (no 24hr circulation pump)

Pump 1B button: Push to turn ON/OFF additional pump (if fitted)

2.1.4 Single Speed (24hr circulation pump fitted)

Pump 1A button: Push button to turn pump ON/OFF

Page 4

Pump 1A button: Push to turn pump ON/OFF

Pump 1B button: Push to change pump speed (LOW, HIGH)

Pump 1B button: Push to turn ON/OFF additional pump (if fitted)

Pump 1A button: Push to change pump mode (PUMP AUTO, MANUAL ON ,MANUAL OFF)

Pump 1A button: Push to change pump mode (PUMP AUTO, MANUAL ON ,MANUAL OFF)

2.3 Aux (Pump, Blower, Light)

Push button to turn Aux output ON/OFF

For more detailed information please see section 3.

2.2.2 Two Speed Pump

2.2.1 Single Speed Pump

Pump 2A button: Push to turn ON/OFF additional pump (if fitted)

Pump 2B button: Push to turn ON/OFF additional pump (if fitted)

Pump 2A button: Push to turn pump ON/OFF

Pump 1B button: Push to change pump speed (LOW, HIGH)

2.1 Pump 1 Operation

2.2 Pump 2 Operation

For more detailed information please see section 4.

For more detailed information please see section 3.

9. LD.

DEFAULTS

- - - -

(SET)

(

)

(

)

[NO]

(

)

(

)

- - - -

ARE YOU SURE?

Push 9

Scroll to SET

NO

[YES]

[

]

1. SET TEMP
2. USER TIMER
3. CLOCK
4. USER ALARM
5. SLEEP TIMES
6. MAINT TIMERS
7. MISC OPTIONS
8. ADV. OPTIONS
9. LD. DEFAULTS

Page 29

Select MAIN menu then push UP button nine times

7.10 Load Factory Default Settings

The load defaults option provides a way of restoring all factory default settings. These include obvious set up
parameters such as set temperature and sleep times but also settings such as preferred light mode, light effect
speeds and blower speed will be restored to their factory defaults. Only use this option if you are absolutely sure it is
necessary.

7.10.1 Restoring Factory Defaults

1) Select the LD. DEFAULTS item from the main menu.(see below for details)
2) Press the SCROLL button. Note that the confirmation prompt uses a very short timeout (approximately three

seconds) and as such you will have to execute the following steps relatively quickly.

3) Press the UP or DOWN button to select “YES”.
4) Press the SCROLL button to load the defaults. The display will temporarily show “DEFAULTS LOADED” to

confirm that defaults have been loaded.

Notes
1) After the defaults have been loaded, it takes approximately 10 seconds for the controller to save them. Do not

turn off the power before this period elapses.

2) The clock hour, minute and weekday will not be reset when you load the defaults

Содержание SPI200 Series

Страница 1: ...to the above values to ensure a healthyexperiencebothforyouasbathersandforyourspapoolequipment Damage to the element thermostat pockets and associated metalwork due to the poor maintenanceofwaterchem...

Страница 2: ...ll a problem then contact your spa pool supplier Error 6 THERMAL CUT OUT Thermal Cut Out Tripped This error indicates that the safety electromechanical over temperature cut out on the heater has opera...

Страница 3: ...detected in the heater housing On a push of the DOWN button the main pump will run for 10 seconds to try to get water to the heater If successful normal operation will resume If unsuccessful the erro...

Страница 4: ...g any water in the heater housing If no water is being detected the LCD Display will also show WATER PRIMING PLEASE WAIT Heater This LED shows when the heater is on The heater will turn on and off as...

Страница 5: ...touch pad LCD contrast brightness can be manually adjusted if the display appears too dark or light To adjust the contrast follow these steps 1 Press and hold down the LIGHT button This will cycle the...

Страница 6: ...on please see section 3 9 LD DEFAULTS SET NO ARE YOU SURE Push 9 Scroll to SET NO YES 1 SET TEMP 2 USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAUL...

Страница 7: ...hour to ensure filtration times are met similarly a setting of 4 hours indicates that a filtration run will occur once every 4 hours 1 Select the ADV OPTIONS submenu from the main menu 2 Select the F...

Страница 8: ...the controller will attempt to use the high setting whenever heating is required Note that high heat may not always be available due to possible load shedding when accessories are turned on depends on...

Страница 9: ...ton modify light synchronisation setting 4 Use the UP and DOWN buttons to toggle between on and off 5 Press the SCROLL button to set Note This option is only available if a SPVCL Spa Power Variable Co...

Страница 10: ...of touch pad inactivity no button presses the backlight intensity will automatically return to a fixed 34 setting This is to ensure long life of the backlight LEDs As soon as you press a button on th...

Страница 11: ...touch pad inactivity The Air Button controls a Spa Power Variable Speed Blower if fitted It is used to turn the blower on off and select different operating modes Four pushes of the air button cycle t...

Страница 12: ...o SPVCL is fitted then the buttons can still be used to produce lighting effects on the touch pad as though a light was fitted The Light Level button selects the intensity of the light and the Light E...

Страница 13: ...he available colours one at a time without any smooth fading between different colours The UP and DOWN buttons may be used to change the speed of the light effect see section 6 2 1 below LCD Displays...

Страница 14: ...play Notes 1 For correct sleep operation ensure the clock is set correctly You will need to set it the first time the controller is powered up or if the controller has been turned off for a long perio...

Страница 15: ...s Options Menu and Advanced Options Menu These sub menus are accessed via main menu items 4 to 8 respectively Simply select one of these items in the main menu and press the SCROLL button You will now...

Страница 16: ...ry handy feature that is used to silence the spa pool during your hours of sleep While the SP1200 is asleep no automatic heating or filtration maintenance will occur however the spa can still be used...

Страница 17: ...timer by pressing SCROLL again Otherwise wait approximately five seconds for the message to disappear and you will be returned back to the default view with the timer running in the background 7 4 Clo...

Страница 18: ...USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAULTS Page 17 Select MAIN menu then push UP button four times 7 5 User Alarms The SP1200 controller h...

Отзывы: