background image

1. POOL TEMP (default setting, set temp and clock on text lines)
2. SET TEMP (clock and pool temp on text lines)
3. CLOCK (set temp and pool temp on text lines)
4. CYCLING (cycles through the above views 1 – 3 for 10 seconds each)

Page 25

7.8.2 Main Display

The SP1200 touch pad LCD consists of two lines of text and four numerical digits. The display typically shows three
quantities - pool temperature, set temperature and the clock (weekday and time). By default the pool temperature is
displayed on the numerical digits leaving the clock and set temperature on the two lines of text.

If preferred, the user may change the layout so either the set temperature or clock are shown on the main display
(four numerical digits) rather than on the smaller text lines. In addition a cycling mode can be selected whereby each
of the three possible views is presented for 10 seconds each.

Available options:

7.8.3 Changing The Main Display

1)

Select the MISC OPTIONS submenu from the main menu.

2)

Select the MAIN DISPLAY menu item

3)

Press the SCROLL button to begin main display selection.

4)

Use the UP and DOWN buttons to set the desired view.

5)

Press the SCROLL button to confirm the current setting and return to the MISC OPTIONS submenu.

7.8.4 Panel Light Colour And Intensity

The user has the ability to change the touch pad backlight colour and intensity to their preferred settings. Note that
these manual settings will only take effect when either the pool light is off or if the “panel and pool light
synchronisation” option has been disabled

7.8.5 Changing The Touch Pad Backlight Colour

7.8.6 Changing The Touch Pad Backlight Intensity

1) Select the MISC OPTIONS submenu from the main menu.
2) Select the PANEL LIGHT INTENSITY menu item.
3) Press the SCROLL button to begin light intensity adjustment.
4) Use the UP and DOWN buttons to set the light intensity.
5) Press the SCROLL button to confirm the current setting and return to the MISC OPTIONS submenu.

Please note that the backlight intensity setting only has effect when the pool is in use. After 90 minutes of touch pad
inactivity (no button presses) the backlight intensity will automatically return to a fixed 34% setting. This is to ensure
long life of the backlight LEDs. As soon as you press a button on the touch pad your custom setting will be restored.

1) Select the MISC OPTIONS submenu from the main menu.
2) Select the PANEL LIGHT COLOUR menu item
3) Press the SCROLL button to begin light colour selection.
4) Use the UP and DOWN buttons to set the desired colour.
5) Press the SCROLL button to confirm the current setting and return to the MISC OPTIONS submenu.

Push 1

(Pump On)

Push 2

(Pump Off)

Push 3

(Pump Auto)

Push 1

(Pump On)

Push 2

(Pump Off)

Page 8

3.4 Pump 1A & 1B

(Single speed pumps, no 24hr circulation pump fitted)

Three pushes of the Pump 1A button cycles the pump as follows:

LCD displays “PUMP ON”, button LEDs green.

LCD displays “PUMP OFF”, button LEDs off.

LCD displays “PUMP AUTO”, button LEDs green.

Notes:
1) If Pump 1A is left in”PUMP ON or “PUMP OFF” modes, this pump will automatically revert to “Auto” mode after 90

minutes.

2) If the heater element is on, running the pump may cause the heater to load shed and switch off. If this occurs the

Two pushes of the Pump 1B button cycles the pump as follows:

LCD displays “PUMP ON”, button LED green.

LCD displays “PUMP OFF”, button LED off.

Notes:
1) If Pump 1B is left on, this pump will automatically switch off after 25 minutes.
2) If the heater element is on, running the pump may cause the heater to load shed and switch off. If this occurs the

heater will come back on approximately 5 seconds after the pump is deselected.

3.5 Pump 1A & 1B

(Single speed pumps, 24hr circulation pump fitted)

Two pushes of the Pump 1A button cycles the pump as follows:

LCD displays “PUMP ON”, button LED green.

LCD displays “PUMP OFF”, button LED off.

LCD displays “PUMP ON”, button LED green.

LCD displays “PUMP OFF”, button LED off.

Notes:
1) If Pump 1A or Pump 1B is left on, these pumps will automatically switch off after 25 minutes.
2) If the heater element is on, running the pump may cause the heater to load shed and switch off. If this occurs

the heater will come back on approximately 5 seconds after pump is deselected.

Two pushes of the Pump 1B button cycles the pump as follows:

Push 1

(Pump On)

Push 2

(Pump Off)

Push 1

(Pump On)

Push 2

(Pump Off)

Содержание SPI200 Series

Страница 1: ...to the above values to ensure a healthyexperiencebothforyouasbathersandforyourspapoolequipment Damage to the element thermostat pockets and associated metalwork due to the poor maintenanceofwaterchem...

Страница 2: ...ll a problem then contact your spa pool supplier Error 6 THERMAL CUT OUT Thermal Cut Out Tripped This error indicates that the safety electromechanical over temperature cut out on the heater has opera...

Страница 3: ...detected in the heater housing On a push of the DOWN button the main pump will run for 10 seconds to try to get water to the heater If successful normal operation will resume If unsuccessful the erro...

Страница 4: ...g any water in the heater housing If no water is being detected the LCD Display will also show WATER PRIMING PLEASE WAIT Heater This LED shows when the heater is on The heater will turn on and off as...

Страница 5: ...touch pad LCD contrast brightness can be manually adjusted if the display appears too dark or light To adjust the contrast follow these steps 1 Press and hold down the LIGHT button This will cycle the...

Страница 6: ...on please see section 3 9 LD DEFAULTS SET NO ARE YOU SURE Push 9 Scroll to SET NO YES 1 SET TEMP 2 USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAUL...

Страница 7: ...hour to ensure filtration times are met similarly a setting of 4 hours indicates that a filtration run will occur once every 4 hours 1 Select the ADV OPTIONS submenu from the main menu 2 Select the F...

Страница 8: ...the controller will attempt to use the high setting whenever heating is required Note that high heat may not always be available due to possible load shedding when accessories are turned on depends on...

Страница 9: ...ton modify light synchronisation setting 4 Use the UP and DOWN buttons to toggle between on and off 5 Press the SCROLL button to set Note This option is only available if a SPVCL Spa Power Variable Co...

Страница 10: ...of touch pad inactivity no button presses the backlight intensity will automatically return to a fixed 34 setting This is to ensure long life of the backlight LEDs As soon as you press a button on th...

Страница 11: ...touch pad inactivity The Air Button controls a Spa Power Variable Speed Blower if fitted It is used to turn the blower on off and select different operating modes Four pushes of the air button cycle t...

Страница 12: ...o SPVCL is fitted then the buttons can still be used to produce lighting effects on the touch pad as though a light was fitted The Light Level button selects the intensity of the light and the Light E...

Страница 13: ...he available colours one at a time without any smooth fading between different colours The UP and DOWN buttons may be used to change the speed of the light effect see section 6 2 1 below LCD Displays...

Страница 14: ...play Notes 1 For correct sleep operation ensure the clock is set correctly You will need to set it the first time the controller is powered up or if the controller has been turned off for a long perio...

Страница 15: ...s Options Menu and Advanced Options Menu These sub menus are accessed via main menu items 4 to 8 respectively Simply select one of these items in the main menu and press the SCROLL button You will now...

Страница 16: ...ry handy feature that is used to silence the spa pool during your hours of sleep While the SP1200 is asleep no automatic heating or filtration maintenance will occur however the spa can still be used...

Страница 17: ...timer by pressing SCROLL again Otherwise wait approximately five seconds for the message to disappear and you will be returned back to the default view with the timer running in the background 7 4 Clo...

Страница 18: ...USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAULTS Page 17 Select MAIN menu then push UP button four times 7 5 User Alarms The SP1200 controller h...

Отзывы: