background image

Page 28

7.9.4 Changing The High Heat Offset Setting

1) Select the ADV. OPTIONS submenu from the main menu.
2) Select the HIGH HT OFFS menu item.
3) Press the Scroll button to begin high heat offset modification.
4) Use the UP and DOWN buttons to adjust the offset as required. Hold down either button for automatic key press

repeat.

5) Press the SCROLL button to confirm the current setting and return to the ADV. OPTIONS submenu.

7.9.5 Auto Filtration/Sanitising (N/A for 24HR Circ Installations)

Automatic filtration is provided to ensure that the pool water is filtered for at least a minimum time each day
regardless of how often the pool is used for normal operation or how long the pump runs for heat maintenance. If the
pump has not run long enough during normal operation the system will automatically run it for an additional period to
meet the minimum filtration time as specified by the user. This feature is especially useful in warmer climates where
very little automatic heating (and hence water filtration) is necessary to keep the pool water at the set temperature.

Automatic filtration consists of two user adjustable settings - Filtration Time and Filtration Period. These settings are
located in the advanced options submenu.

7.9.6 Adjusting The Filtration Time

The Filtration Time setting specifies the minimum filtration time and can be adjusted between 0 and 30 minutes per
hour (effectively 0 to 12 hours per day), default 10 minutes. A setting of 0 minutes totally disables automatic filtration.

1) Select the ADV. OPTIONS submenu from the main menu.
2) Select the FILT. TIME menu item.
3) Press the SCROLL button to begin Filtration Time modification.
4) Use the UP and DOWN buttons to set the desired filtration time in minutes per hour.
5) Press the SCROLL button to confirm the current setting and return to the ADV. OPTIONS submenu.

7.9.7 Adjusting The Filtration Period

The Filtration Period setting specifies how often the system should run the pump to ensure the minimum filtration time
is met. Available settings are 1, 2, 3 or 4 hours. At the default setting of 1 hour, the pump will come on no more than
once an hour to ensure filtration times are met, similarly a setting of 4 hours indicates that a filtration run will occur
once every 4 hours.

1) Select the ADV. OPTIONS submenu from the main menu.
2) Select the FILT. TIME menu item.
3) Press the SCROLL button to begin Filtration Period modification.
4) Use the UP and DOWN buttons to set the desired filtration period.
5) Press the SCROLL button to confirm the current setting and return to the ADV. OPTIONS submenu.

Please note that although the filtration period restricts how often filtration-only runs occur, normal heating maintenance
may take place in between the filtration runs. If this occurs it may appear as though the filtration period setting is not
functioning correctly, however this behaviour is normal. Excessive cycling of the spa will not be cured by increasing
the filtration period, please read “Heat Control” for more information.
Notes
1)

On every day of the year we experience different ambient temperatures. As a result the spa pump will run for

different periods at different times every day, depending on how often the pump runs to heat the water.

2)

Any modification of filtration settings (either time or period) will cause the current filtration timing to be reset and

automatic filtration maintenance will not continue until the first hour of the next filtration period.

3)

Filtration cycles will always trigger heating if the pool is below the temperature set point regardless of the heat

mode setting.

4)

Filtration does not operate during sleep periods.

Push button to turn blower ON/OFF and select operating mode (HIGH,RAMPING,VARIABLE SPEED)

Light level button: Push to turn light ON/OFF and alter brightness.

Light mode button: Push to change the light effects.

MAIN MENU

- - - -

ESC

(

)

(

)

(

)

Push 1 = Main Menu display appears (see below)

Or

Push 1 = Set Temp display appears (see below)

1.

SET TEMP

(

)

(

)

( SET )

38.00

C

O

Use the up and down buttons to select desired temperature

Push the Scroll button to save the current setting.

Page 5

Push the SCROLL button to alter temperature

For more detailed information please see section 5.

For more detailed information please see section 6.

For more detailed information please see section 6.2

2.4 Variable Speed Blower Operation

2.5 Variable Colour Light Operation

2.6 Setting The Temperature

Use the up and down buttons to adjust the blower speed

Содержание SPI200 Series

Страница 1: ...to the above values to ensure a healthyexperiencebothforyouasbathersandforyourspapoolequipment Damage to the element thermostat pockets and associated metalwork due to the poor maintenanceofwaterchem...

Страница 2: ...ll a problem then contact your spa pool supplier Error 6 THERMAL CUT OUT Thermal Cut Out Tripped This error indicates that the safety electromechanical over temperature cut out on the heater has opera...

Страница 3: ...detected in the heater housing On a push of the DOWN button the main pump will run for 10 seconds to try to get water to the heater If successful normal operation will resume If unsuccessful the erro...

Страница 4: ...g any water in the heater housing If no water is being detected the LCD Display will also show WATER PRIMING PLEASE WAIT Heater This LED shows when the heater is on The heater will turn on and off as...

Страница 5: ...touch pad LCD contrast brightness can be manually adjusted if the display appears too dark or light To adjust the contrast follow these steps 1 Press and hold down the LIGHT button This will cycle the...

Страница 6: ...on please see section 3 9 LD DEFAULTS SET NO ARE YOU SURE Push 9 Scroll to SET NO YES 1 SET TEMP 2 USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAUL...

Страница 7: ...hour to ensure filtration times are met similarly a setting of 4 hours indicates that a filtration run will occur once every 4 hours 1 Select the ADV OPTIONS submenu from the main menu 2 Select the F...

Страница 8: ...the controller will attempt to use the high setting whenever heating is required Note that high heat may not always be available due to possible load shedding when accessories are turned on depends on...

Страница 9: ...ton modify light synchronisation setting 4 Use the UP and DOWN buttons to toggle between on and off 5 Press the SCROLL button to set Note This option is only available if a SPVCL Spa Power Variable Co...

Страница 10: ...of touch pad inactivity no button presses the backlight intensity will automatically return to a fixed 34 setting This is to ensure long life of the backlight LEDs As soon as you press a button on th...

Страница 11: ...touch pad inactivity The Air Button controls a Spa Power Variable Speed Blower if fitted It is used to turn the blower on off and select different operating modes Four pushes of the air button cycle t...

Страница 12: ...o SPVCL is fitted then the buttons can still be used to produce lighting effects on the touch pad as though a light was fitted The Light Level button selects the intensity of the light and the Light E...

Страница 13: ...he available colours one at a time without any smooth fading between different colours The UP and DOWN buttons may be used to change the speed of the light effect see section 6 2 1 below LCD Displays...

Страница 14: ...play Notes 1 For correct sleep operation ensure the clock is set correctly You will need to set it the first time the controller is powered up or if the controller has been turned off for a long perio...

Страница 15: ...s Options Menu and Advanced Options Menu These sub menus are accessed via main menu items 4 to 8 respectively Simply select one of these items in the main menu and press the SCROLL button You will now...

Страница 16: ...ry handy feature that is used to silence the spa pool during your hours of sleep While the SP1200 is asleep no automatic heating or filtration maintenance will occur however the spa can still be used...

Страница 17: ...timer by pressing SCROLL again Otherwise wait approximately five seconds for the message to disappear and you will be returned back to the default view with the timer running in the background 7 4 Clo...

Страница 18: ...USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAULTS Page 17 Select MAIN menu then push UP button four times 7 5 User Alarms The SP1200 controller h...