4: Maintenance
4-2
PRC1077-MSOP
•
Remove dust and loose dirt with a clean, soft cloth.
•
Remove grease, fungus, and ground-in dirt from the case using a cloth
dampened with trichlorethane.
CAUTION: TRICLORETHANE fumes are toxic. Make sure the area
of use has adequate ventilation. Exposure to open flame converts
TRICLORETHANE to a highly toxic and dangerous gas.
•
Remove dust and dirt from plugs and receptacles.
•
Clean the front panel and control knobs using a soft clean cloth. If the dirt
is difficult to remove, dampen the cloth with mild detergent and water.
Operational
Checklist
Make the following operational checks before and after using the PRC1077. If
the PRC1077 or any accessory fails to function correctly report the failure to
technical personnel.
1. Connect the handset.
2. Install the antenna.
3. Set the Volume knob to 5.
4. Set the Channel switch to any channel.
5. Set the Power knob to LO, MED or HIGH. The frequency displayed in
the LCD should match the frequency of the channel to which the Channel
switch is set. If the displayed frequency does not match the frequency of
the channel, reset the channel frequency. If the displayed frequency is still
not correct, replace the battery.
6. Set the Function switch to LITE. The LCD should be backlit. If the LCD
does become backlit, notify technical personnel
7. Set the Function switch to SQUELCH. The background noise should
stop. If the background noise does not stop, notify technical personnel
8. Listen to test signals transmitted from a nearby radio set operating at the
frequency (simplex operation) displayed on the LCD. If the transmissions
are not heard clearly, check the antenna connection for looseness. If the
audio is still not clear, notify technical personnel.
9. Transmit a test signal to a nearby radio set. If you do not hear a side tone
or get a response from the test radio:
•
Check the antenna connection for looseness
•
Replace the battery
•
Notify technical personnel
10. With the Function knob set to TONE, repeat steps 8 and 9.