1
Setting up the machine
Room climate
1-2
DATRON AG
Setup instructions neo
1.21
1.3
Room climate
NOTE
Air should be free of aggressive dusts and gases.
Required room climate:
Temperature
18 - 30 °C
Humidity
< 65 % rel.
Make sure the room temperature is sufficient. The ideal room
temperature is 20 - 23 °C. The machine must be completely at
room temperature before commissioning. For perfect operation,
the spindles require a coolant temperature of at least 18 °C, ideal
would be 25 °C.
If there is a risk of frost during storage or transport of the DATRON
machine, the cooling water must be completely drained out of the
machine and the cooling device beforehand.
Venting the set-up location
Make sure there is good ventilation in the set-up environment.
When machining materials which release harmful dusts, the dusts
which are formed must be suctioned off. Observe the statutory
regulations.
The following must be observed when the machine is operated
with cooling lubricant:
During continuous machine operation the area around the
machine must be well ventilated or an exhaust system for the
removing the cooling lubricant vapour must be installed. When
installing the room exhaust system, note whether the cooling
lubricant in use is lighter or heavier than air. Install the room
exhaust system at the top or bottom as applicable. The AGW
values (maximum workplace concentration values) of the cooling
lubricant must be below the maximum limit.
In HVAC technology, the following general empirical values are
used for the air exchange numbers (i.e. exchanged air per hour):
Содержание neo
Страница 1: ...DATRON neo Setup instructions ...
Страница 4: ...i Contents i 2 DATRON AG Setup instructions neo 1 21 ...
Страница 8: ...1 Setting up the machine Screen 1 4 DATRON AG Setup instructions neo 1 21 ...
Страница 16: ...2 Connecting the supply media Chip suction 2 8 DATRON AG Setup instructions neo 1 21 ...
Страница 24: ...5 Vacuum cleaner optional 5 2 DATRON AG Setup instructions neo 1 21 ...