1 DATECS
LP-50
36
p
7
(c)
Data compression method.
c0
Auto-encoding (default).
c1
Binary mode.
p
8
(p)
Print human readable data. Non-standard PDF417
and should be used for troubleshooting purposes
only.Internal format:
px,y,n
x
X start coordinate. 0 – 2047.
y
Y start coordinate. 0 – 4095.
n
Maximum characters per line. 1 – 40.
p
9
(f)
Bar-code origin point.
f0
Bar-code origin point is defined by
parameters
p
1
and
p
2
.
f1
Bar-code is centered in the rectangle, defined
by
p
1
,
p
2
,
p
4
and
p
5
. This is the default.
p
10
(x)
Set maximum module width (in dots). Allowed values:
x2 to x9. Default: x6.
p
11
(y)
Set maximum bar height (in dots). Allowed values: y4
to y99. Default is 4 times module width (4*p
10
).
p
12
(r)
Set maximum row count. Allowed values: r3 to r90.
Default: r90.
p
13
(l)
Set maximum column count. Allowed values:
l5 to l34. Default: l34.
p
14
(o)
Rotation. Allowed values:
o0
: 0,
o1
: 90,
o2
: 180,
o3
:
270 degrees. Default
o0
.
Data
Contains bar-code data. The format is the same as
the data format for text and bar code, but it is
possible additionally to encode non printable
characters (with ASCII codes below 32) using the
syntax ‘
\dd
’, where
dd
is the decimal representation
of the ASCII code.
If the bar-code with the selected module width and height fits
not in the area, defined by
p
1
,
p
2
,
p
4
and
p
5
, the printer
automatically starts to lower
p
10
and
p
11
until the area of the
bar-code becomes small enough to be printed. Row and
column count are calculated so the proportions of the bar-
code are as near as possible to
p
4
: p
5
. If this procedure fails,
the bar-code is not printed.
Содержание LP-50
Страница 1: ...1 DATECS Bulgaria User s Manual LABEL PRINTER MODEL LP 50...
Страница 4: ...1 DATECS LP 50 4...