41
T-Bar Re-Calibration
After a firmware update of the switcher it will be necessary to re-calibrate the T-Bar to get it working
correctly.
1.
Move the
T-Bar
to its
lowest position
.
2.
Power OFF
the HS-2200 switcher.
3.
Press and
hold down BK button on both the Program and
Preset
rows of the switcher’s keyboard.
4.
Power ON
the HS-2200 switcher while
still holding down the
buttons
in step 3.
5.
The switcher will start but the keyboard lights will remain
dead except for the T-Bar progress LEDs. When these
LEDs
flash ON and OFF
release the buttons from step 3.
6.
Move the
T-Bar
to its
top position
and then press the
CUT
button
.
7.
Move the
T-Bar
back to its lowest position
and then press
the
AUTO TAKE button
.
8.
To exit the calibration procedure, press the
CLOCK button
.
9.
Ensure the
TIMER button
is
OFF
.
10.
Test the T-Bar.
If necessary change the
T-Bar Mode
in the
OSD
MENU
options
.