background image

PAGE 5

3.0 - ACCESSORIES POSITIONING

3.2

 

-

 

Contact

 

switch

 

(

Thatcham Requirement

)

If Thatcham accreditation is not a requirement the fitting of the switch is 

optional but strongly recommended.  If the switch is not fitted, the 

GREEN/BROWN wire should be insulated but  remain free for other 

possible uses such as programming the alarm or learning new devices.

NB:

A contact switch can be must be fitted to protect the alarm ECU. It must be 

installed in such a way as to detect the opening of the seat or panel without 

being accessible from the outside. The trigger threshold must be carefully 

set to avoid false alarms.

Do not ground the switch terminal to the vehicle frame make a connection to 

earth through a negative cable such as the indicator lamp negative lead.

Override

key

PAGE 4

Override key

Example of receptacle positioning on the vehicle

plastic side cover

4.0 - ALARM UNIT SEALING

Alarm unit sealed

To seal the alarm, position the

rubber cap over the external edge

of the alarm housing.

Pull the plastic rectangular flange

over the rubber cap and secure

with the supplied screws.

Do not over tighten.

3.1 - Override key receptacle

The receptacle with built-in LED must be installed where it can readily be seen

and accessed by the user. Before drilling a hole in the plastic dash with a 13mm

drill bit, check the position of the handlebars with the steering lock engaged.

Make sure the LED will not be covered by the handlebars when the vehicle is

parked.

Содержание EVO PRO

Страница 1: ...Installation Guide Datatool is a brand of Scorpion Automotive www datatool com 01257 249928 Scorpion House Drumhead Road Chorley PR6 7DE P N 02000147 Rev 01 07 22 ...

Страница 2: ...following signal words are used throughout this manual to emphasize important instructions or special information 2 0 ALARM POSITIONING Fit th alarm as shown in the picture opposite to prevent water entering the unit Give the a goose neck bending as shown and secure with a tie wrap e Do not install the rubber sheath The alarm unit must be installed in such a way as not to muffle the siren but it m...

Страница 3: ...he switch terminal to the vehicle frame make a connection to earth through a negative cable such as the indicator lamp negative lead Override key PAGE 4 Override key Example of receptacle positioning on the vehicle plastic side cover 4 0 ALARM UNIT SEALING Alarm unit sealed To seal the alarm position the rubber cap over the external edge of the alarm housing Pull the plastic rectangular flange ove...

Страница 4: ...ation OK OK OK OK OK Figure 5 motion sensor operation with alarm fitted vertically only for vehicles with a centre stand To prevent water from entering the unit the wire rubber sheath must be turned downwards NOTE Prior to fitting test the operation of the sensor to confirm it will work in the intended position 5 Figure 4 motion sensor operation with siren facing sideways only for vehicles with a ...

Страница 5: ...ect to starter motor side Ignition key Vehicle battery Black marked HB Black marked H1 Normally closed contact Black marked B1 Black marked H Normally open contact Common contact Common contact Normally open contact Black marked B Orange Orange 10A Black marked R Battery 12 Volt Black marked M Black marked G Green Brown Ground Engine immobilizer 15A 15A Receptacle with built in LED Override key la...

Страница 6: ...ngine engine BLACK H1 N O BLACK B1 COM BLACK HB BLACK H N C BLACK B COM 8 1 Electronic ignition Example N 1 PAGE10 N C GROUND IGNITION STARTER SWITCH NOTE above examples are merely indicative and not restrictive BLACK BLACK MARKED MARKED B1 B1 MARKED MARKED B B BLACK BLACK BLACK BLACK MARKED MARKED H1 H1 BLACK BLACK MARKED HB 15 54 15 54 IGNITION IGNITION 8 2 Grounded Wire Example N 1 Example N 2 ...

Страница 7: ...emote controls and 1 override key but other optional devices can be added CAUTION Alarm memory will only store 8 devices Saving an extra device will automatically delete the first one To pair a new device proceed as follows Make sure passive immobilisation is not active Arm and then disarm the alarm via remote control or override key Lift the seat or open the topcase or if there is no contact swit...

Страница 8: ...n the last feature is programmed the system automatically exits the programming mode Three followed by will confirm the end of the procedure T status LED will also OFF exit ignition P f NB To help you understand the programming procedure here below is an example showing how to enable both features Keep in mind that at every button press the system automatically scrolls to the next feature ift the ...

Страница 9: ...irective The crossed out wheeled bin symbol on the equipment or on its packaging indicates that the product at the end of its useful life must be discarded separately from other waste to allow adequate treatment and recycling The user must therefore take the equipment at the end of its useful life to an appropriate waste collection facility The remote control has a low charge battery indicator tha...

Отзывы: