12.0 - REMOTE CONTROL

The remote control has 2 different function buttons each of which corresponds

to a control signal that activates a selected action according to the operational

condition and alarm configuration.
The textured button is for arming/disarming the alarm while the smooth button

is used to exclude or trigger the siren.

Button 1

LED

indicator

Button 2

Button 1

Button

:

2:

• Arm/disarm alarm unit

• Trigger/Stop p

alarm

• Exclude siren (mute alarm)

anic

• Activate Hazard lights

Separate the shell

halves taking care

not to damage the

internal circuit.

Close the plastic

shells and make

sure the remote

works properly.

Remove the

discharged batteries

and insert the new

ones taking care not to

invert the polarity.

13.0 - WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT

The present device falls within the field of application of the current WEEE

Directive. The crossed-out wheeled bin symbol on the equipment or on its

packaging indicates that the product, at the end of its useful life, must be

discarded separately from other waste to allow adequate treatment and

recycling.

The user must therefore take the equipment, at the end of its useful life, to an

appropriate waste collection facility.

The remote control has a low charge battery indicator that gives you early

warning to avoid malfunctioning. When the batteries are fully charged, the LED

will show a steady light at the press of a button. If the batteries are too weak for

normal operation, the LED will start blinking at the press of a button. To replace

the batteries proceed as follows:

BATTERIES

12 Vdc

< 1mA (alarm armed and LED flashing)

< 1µA

118 dBA @ 1 meter

8A

14.0 - TECHNICAL SPECIFICATIONS

Nominal supply voltage

Load @ 12Vdc

Load in sleep mode

Siren output level

Relay capacity

WARNING

!

U

.

se only CR1616 batteries.

Different type batteries can seriously damage the remote control unit.

Discard used batteries properly in special dedicated containers

Содержание EVO PRO

Страница 1: ...Installation Guide Datatool is a brand of Scorpion Automotive www datatool com 01257 249928 Scorpion House Drumhead Road Chorley PR6 7DE P N 02000147 Rev 01 07 22 ...

Страница 2: ...following signal words are used throughout this manual to emphasize important instructions or special information 2 0 ALARM POSITIONING Fit th alarm as shown in the picture opposite to prevent water entering the unit Give the a goose neck bending as shown and secure with a tie wrap e Do not install the rubber sheath The alarm unit must be installed in such a way as not to muffle the siren but it m...

Страница 3: ...he switch terminal to the vehicle frame make a connection to earth through a negative cable such as the indicator lamp negative lead Override key PAGE 4 Override key Example of receptacle positioning on the vehicle plastic side cover 4 0 ALARM UNIT SEALING Alarm unit sealed To seal the alarm position the rubber cap over the external edge of the alarm housing Pull the plastic rectangular flange ove...

Страница 4: ...ation OK OK OK OK OK Figure 5 motion sensor operation with alarm fitted vertically only for vehicles with a centre stand To prevent water from entering the unit the wire rubber sheath must be turned downwards NOTE Prior to fitting test the operation of the sensor to confirm it will work in the intended position 5 Figure 4 motion sensor operation with siren facing sideways only for vehicles with a ...

Страница 5: ...ect to starter motor side Ignition key Vehicle battery Black marked HB Black marked H1 Normally closed contact Black marked B1 Black marked H Normally open contact Common contact Common contact Normally open contact Black marked B Orange Orange 10A Black marked R Battery 12 Volt Black marked M Black marked G Green Brown Ground Engine immobilizer 15A 15A Receptacle with built in LED Override key la...

Страница 6: ...ngine engine BLACK H1 N O BLACK B1 COM BLACK HB BLACK H N C BLACK B COM 8 1 Electronic ignition Example N 1 PAGE10 N C GROUND IGNITION STARTER SWITCH NOTE above examples are merely indicative and not restrictive BLACK BLACK MARKED MARKED B1 B1 MARKED MARKED B B BLACK BLACK BLACK BLACK MARKED MARKED H1 H1 BLACK BLACK MARKED HB 15 54 15 54 IGNITION IGNITION 8 2 Grounded Wire Example N 1 Example N 2 ...

Страница 7: ...emote controls and 1 override key but other optional devices can be added CAUTION Alarm memory will only store 8 devices Saving an extra device will automatically delete the first one To pair a new device proceed as follows Make sure passive immobilisation is not active Arm and then disarm the alarm via remote control or override key Lift the seat or open the topcase or if there is no contact swit...

Страница 8: ...n the last feature is programmed the system automatically exits the programming mode Three followed by will confirm the end of the procedure T status LED will also OFF exit ignition P f NB To help you understand the programming procedure here below is an example showing how to enable both features Keep in mind that at every button press the system automatically scrolls to the next feature ift the ...

Страница 9: ...irective The crossed out wheeled bin symbol on the equipment or on its packaging indicates that the product at the end of its useful life must be discarded separately from other waste to allow adequate treatment and recycling The user must therefore take the equipment at the end of its useful life to an appropriate waste collection facility The remote control has a low charge battery indicator tha...

Отзывы: