Autoping Commands
These commands require a reboot before they will take effect.
These commands are available to the administrator only.
get autoping
This command returns all of the AutoPing settings as shown below.
Autoping 1 A B
Address: iboot.co
Frequency: 10 10
Fail Count: 3 3
Logic: A Only
Action: Cycle
Cycle: 1
Outlet: Main
Wait: 2
Restart: 0
Status: OK
Trig Count: 0
Autoping 2
Address:
Frequency: 10
Fail Count: 3
Action: None
Cycle: 1
Outlet: Exp1
Wait: 2
Restart: 0
Status: OK
Trig Count: 0
Autoping 3
Address:
Frequency: 10
Fail Count: 3
Action: None
Cycle: 1
Outlet: Exp1
Wait: 2
Restart: 0
Status: OK
Trig Count: 0
set autoping <1a | 1b | 2 | 3> address
<domain|dotted decimal>
This command is used to set the address of AutoPing.
Domain name or ipaddress.
0.0.0.0
set autoping <1a | 1b | 2 | 3> frequency
<1-999>
This command is used to set the frequency, in
seconds (how often the iBoot-G2+ sends the ping) for
each of the AutoPings.
10
set autoping <1a | 1b | 2 | 3> failcount <1-
999>
This command is used to set the number of
consecutive failures the AutoPings must detect before
the AutoPing considers the pinged device to be failed.
3
set autoping 1 logic <a | and | or>
Sets logic for AutoPing 1. A = A Only, and = A and B,
or = A or B.
A and B
set autoping <1 | 2 | 3> outlet <main | exp1
| exp2>
This command sets the outlet that the AutoPing will
trigger.
Main
set autoping <1 | 2 | 3> action <none | on-
latch | on-follow | off-latch | off-follow |
cycle>
This command is used to set the action that the iBoot-
G2+ will perform when the AutoPing triggers.
None
set autoping <1 | 2 | 3> cycle <0-999>
This command sets the maximum number of power
cycles when the AutoPing triggers. 0 = Unlimited
1
set autoping <1 | 2 | 3> wait <1-999>
This command sets the time, in seconds for the device
to respond to a ping.
2
set autoping <1 | 2 | 3> restart <1-999>
After an autoping has been triggered, this command
sets the time, in seconds before the autoping will
resume. (added delay after cycle complete)
0