iBoot-G2+ / iBoot-G2S
Page 16
iBoot Expansion Units
This mode is default and is used with the
iBoot-EXP devices. The Main page will show
status and allow control for the Main, Exp1 and
Exp2 outlets.
Hide from Status and Control: Independantly
hide the status of Exp1 and Exp2 from the Main
Status and Contol webpage. Checking the box to
hide the status is available as an option should
you not be using the expansion capabilities of the
iBoot-G2+ device. Hiding the status does not
prevent the function of Expansion units should
they be attached. this allows for linked outlets to
be hidden, but still function.
Link to Main: Checking the box for Link to Main will independently make the status of the Expansion unit be
identical to the Main outlet of iBoot-G2+. This is convenient if switching both power supplies of dual redundant
powered devices. The delay time will apply.
Independent I/O
This mode will display the input and output status
for Exp1 and Exp2 on the status and control page.
The open collector design of the output
connectors can be used to control non-Dataprobe
devices, or connected to a Dataprobe external
relay module to allow relay control of those
devices. The input status can also be used to
contol Dataprobe devices that support DxP
protocol. Allowing a switch connected to the Exp
connector to control a remote Power Outlet or
relay on any DxP controlled device.
Hide from Status and Control: Independantly hide
the status of Exp1 and Exp2 from the Main Status and Contol webpage. Checking the box to hide the status is
available as an option should you not be using the expansion capabilities of the iBoot-G2+ device. Hiding the
status does not prevent the function of I/O should connections be attached or programmed.
To allow the inputs of Exp1 and Exp2 to control additional devices via DxP Protocol, enter the IP address,
relay number, user name and password for the device to be controlled.
See Expansion Connections
section 4.3
for details on the Exp connectors and the open collector output.