2. Important Safety Instructions 

 

When using this product, basic safety precautions should always be followed to reduce the risk of fire, 
electric shock, and injury to persons, including the following: 

 

1. 

Read and understand all instructions. 

2. 

Follow all warnings and marked on the product.  

3. 

Unplug this product from the wall outlet before cleaning.  Do not use liquid cleaners or aerosol cleaners.  Use a damp cloth 
for cleaning. 

4. 

Do not use this product in an outdoor environment or near water, for example, near a bath tub, wash bowl, kitchen sink, or 
laundry tub, in a wet basement, or near a swimming pool. 

5. 

Do  not  place  this  product  on  an  unstable  cart,  stand,  or  table.    The  product  may  fall,  causing  serious  damage  to  the 
product. 

6. 

Slots and openings in this product and the back or bottom are provided for ventilation to protect it from overheating; these 
openings must not be blocked or covered.  The openings should never be blocked by placing the product on the bed, sofa, 
rug, or other similar surface.  This product should never be placed near or over a radiator or heat register.  This product 
should not be placed in a built-in installation unless proper ventilation is provided. 

7. 

This product should be operated only from the type of power source indicated on the marking label.  If you are not sure of 
the type of power supply to your home, consult your dealer or local power company. 

8. 

This product is equipped with a three wire grounding type plug, a plug having a third (grounding) pin.  This plug will only fit 
into a grounding type power outlet.  This is a safety feature.  If you are unable to insert the plug into the outlet, contact your 
electrician to replace your obsolete outlet.  Do not defeat the safety purpose of the grounding type plug.  Do not use a 3-to-
2  prong  adapter  at  the  receptacle;  use  of  this  type  adapter  may  result  in  risk  of  electrical  shock  and/or  damage  to  this 
product. 

9. 

Do  not  allow  anything  to  rest  on  the  power  cord.    Do  not  locate  this  product  where  the  cord  will  be  abused  by  persons 
walking on it. 

10. 

Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.  

11. 

Never  push  objects  of  any  kind  into  this  product  through  slots  as  they  may  touch  dangerous  voltage  points  or  short  out 
parts that could result in a risk of fire or electrical shock.  Never spill liquid of any kind on the product. 

12. 

To  reduce  the  risk  of  electrical  shock,  do  not  disassemble  this  product,  but  take  it  to  a  qualified  serviceman  when  some 
service  or  repair  work  is  required.    Opening  or  removing  covers  may  expose  you  to  dangerous  voltages  or  other  risks.  
Incorrect re-assembly can cause electric shock when the appliance is subsequently used.  

13. 

Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: 
a)   

When the power supply cord or plug is damaged or frayed. 

b)   

If liquid has been spilled into the product. 

c)  

If the product has been exposed to rain or water. 

d)  

If  the  product  does  not  operate  normally  by  following  the  operating  instructions.    Adjust only  those  controls  that 
are  covered  by  the  operating  instructions  because  improper  adjustment  of  other  controls  may  result  in  damage 
and will often require extensive work by a qualified technician to restore the product to normal operation. 

e)  

If the product has been dropped or has been damaged. 

f)  

If the product exhibits a distinct change in performance. 

14.  

Avoid  using  a  telephone  (other  than  a  cordless  type)  during  an  electrical  storm.    There  may  be  a  remote  risk  of  electric 
shock from lightning. 

15.  

Do not use the telephone to report a gas leak in the vicinity of the leak. 

16.  

Do not exceed the maximum output rating of the auxiliary power receptacle. 

 
 

Save These Instructions 

 

 

Содержание iBoot-G2S

Страница 1: ...on Eliminates port forwarding and security issues Telnet setup and control of all fuctions Allows easy scripting Network Switch Built in 2 Port 10 100 Network Switch iBoot G2S only Eliminates need fo...

Страница 2: ...to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this...

Страница 3: ...ipment when not needed for power savings and to save on wear and tear Power up alert devices like sirens lamps messages or control environmental system like heaters coolers pumps etc 3 2 Multiple Cont...

Страница 4: ...n Ports on the iBoot G2 can be used as general purpose I O GPIO to monitor and control additional devices Inputs on the expansion ports can be used to monitor alarm contacts environmental sensors rela...

Страница 5: ...ndicate when the network connection is properly established and when the connection is 100 Mbit s 4 2 AC Power Connections Connect the device to be powered ON and OFF to the IEC receptacle marked A C...

Страница 6: ...terminals are tightened securely and that there are no loose strands of cable or excessive stripped wires Connecting to iBoot Exp Terminal blocks are connected pin to pin with the iBoot Exp as shown...

Страница 7: ...l Connection to a PC for heartbeat monitoring To use the USB port connect to a Windows PC and the installation should be automatic If you need to install a driver first you can download the driver at...

Страница 8: ...stalling the Wall Mounting Kit DIN Rail Mounting 1 Remove the four mounting screws from the underside of the unit Do not disassemble the unit 1 Install the Wall Mounting Kit as shown use steps 1 3 to...

Страница 9: ...3 Run the DMU Note The DMU can only set the IP address within the first two minutes of powering up or rebooting the iBoot The DMU will only work with iBoots on the same physical subnet as the PC Once...

Страница 10: ...cover again to refresh the display highlight the desired iBoot G2 and click on Manage Launch Browser see Web Setup section 7 to configure the iBoot The DMU can also be used to return an iBoot G2 to it...

Страница 11: ...ture When there is no activity for the set time in minutes the user is automatically logged out and the username and password will need to be entered again for access This is to prevent accidental loc...

Страница 12: ...d click on the appropriate button If an outlet is linked to the Main outlet an Linked to Main message will replace the checkbox as shown for Exp1 and it will be managed in sync with the Main Outlet A...

Страница 13: ...orner Logout When you are finished with iBoot click on Logout A Goodbye page will be displayed This page has a URL link to re connect with the iBoot The linkback URL is user settable If no linkback is...

Страница 14: ...ollows location id Command Received The full http response is DOCTYPE html PUBLIC W3C DTD XHTML 1 0 Transitional EN http www w3 org TR xhtml1 DTD xhtml1 transitional dtd html xmlns http www w3 org 199...

Страница 15: ...he iBoot G2 is powered up or reset The choices are On Off and Last meaning the state it was in when the power was removed or reset commenced Upgrade Enable Check this box to allow remote firmware upgr...

Страница 16: ...play the input and output status for Exp1 and Exp2 on the status and control page The open collector design of the output connectors can be used to control non Dataprobe devices or connected to a Data...

Страница 17: ...ent the function of inputs or outputs should connections be attached or programmed The power is controlled when the input is connected to ground This makes momentary switches preferred for power contr...

Страница 18: ...e URL If you set any HTTP Port other than Web standard 80 you must append to the URL examples myiboot com myiboot com 8080 Telnet Port This setting is used to allow access to the iBoot G2 via telnet b...

Страница 19: ...r Time Server This field is for the desired time Server to be accessed time nist gov is the default You may enter a Domain Name or ip in this field Time Zone This field is for the Time zone of the uni...

Страница 20: ...t Hard Reboot Delay When an outlet is On and you select cycle from any control method this is the time in seconds for the iBoot to wait for a graceful reboot to successfully complete If the graceful r...

Страница 21: ...nter 1 999 times the ping needs to fail consecutively before the selected action is taken When the fail count has been reached the AutoPing action will be triggered Mode AutoPing 1 only Select from A...

Страница 22: ...number of intervals it will perform its programmed action Use the heartbeat to insure that you server is running When the server crashes it will be automatically rebooted The heartbeat can be generat...

Страница 23: ...to indicate that iBoot G2 is receiving heartbeats or that the fail counter has not yet been exceeded If the fail count has been exceeded the status will change to Triggered The Trigger Counter indica...

Страница 24: ...and Admin users Each user has a settable password Auto Login This mode does not require a username or password for the User level operation No login challenge will be required for any mode of operati...

Страница 25: ...ion will not allow programming for On Follow Off Latch or Off Latch If a Schedule Settings event has action for Off it will be reprogrammed for On Schedule Settings will not allow programming for acti...

Страница 26: ...ram the name of the device a reboot is required to apply the new name as the LLMNR for the device The LLMNR name does not allow spaces If using the LLMNR feature to access the iBoot G2 do not use a sp...

Страница 27: ...ent users free of charge and is evolving Screenshots below may be improved as time has passed since development of this manual The full Terms of Service of the iBoot Cloud Service is available here 8...

Страница 28: ...Dataprobe support pages e Control Power from the Cloud The status screen will detail all the iBoots registered with the cloud You can add locations and group iBoots by location Each iBoot displays th...

Страница 29: ...he COM port assigned to the iBoot G2 The communications parameters are 9600bps 8 data bits No parity 1 Stop bit No Flow Control Once the connection is made send Enter The CLI uses the same security op...

Страница 30: ...tput Closed Exp2 Input Open Output Open Device Commands Set commands are available to the administrator only set location 20 char max This command is used to set the iBoot G2 s location ID this is use...

Страница 31: ...bled No IP Address 0 0 0 0 Username Password Hard Shutdown Delay 120 Hard Reboot Delay 120 Exp1 Enabled No IP Address 0 0 0 0 Username Password Hard Shutdown Delay 120 Hard Reboot Delay 120 Exp2 Enabl...

Страница 32: ...and sets the Exp1 or Exp2 to be linked to the main outlet for simultaneous control This command takes effect only when expansion mode is iBoot Expansion Units no set expansion exp1 exp2 ipaddress dott...

Страница 33: ...server listens for incoming connections on When set to 0 the web server is disabled 80 set telnet port 0 65535 This command sets the port that the iBoot G2 s Telnet server listens for incoming connect...

Страница 34: ...seconds how often the iBoot G2 sends the ping for each of the AutoPings 10 set autoping 1a 1b 2 3 failcount 1 999 This command is used to set the number of consecutive failures the AutoPings must det...

Страница 35: ...detect before the iBoot G2 considers the device to be failed 3 set heartbeat action none on latch on follow off latch off follow cycle This command is used to set the action that the iBoot G2 will pe...

Страница 36: ...Daylight savings start and stop commands above use the following key week is 1 5 day is 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday month is 1 12 time is HH MM using 24 hou...

Страница 37: ...Password This prompts the user to enter his password iBoot This is the prompt that will be displayed after the user has successfully logged in iBoot Reboot Required This is the prompt that will be di...

Страница 38: ...eset the iBoot G2 to factory defaults Check the release notes for the upgrade before making changes to you iBoot G2 1 Insure that the Upgrade Enable checkbox is checked in the Network Setup web page o...

Страница 39: ...lows Action Result Momentary Soft Reset Will not change outlet status 5 Seconds push Reset to Factory Defaults Hold the button in until the Outlet LED is blinking then release Hold in while and Power...

Страница 40: ...is 12 VDC power out from the iBoot G2 Maximum current 100 mA Feedback I Input Input for status signals Dry Contact input or Open Collector Ground G Ground Signal Ground for Input and Output Command O...

Страница 41: ...r this Warranty is obtained by contacting your Authorized Dataprobe Reseller THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EX...

Отзывы: