The iB-30 is an high power version of our iBoot-G2 Web Enabled Power Switch.  Anyone with a web 
browser can access iB-30 to perform power On, Off or Power Cycle (Reboot or Power Burst). The  iB-
30 uses two levels of password for security.    
 
The iB-30 will allow a user to turn on and off a 120/240 VAC powered device with a maximum current 
draw of up to 30 Amps.  A simple Web browser interface makes it easy to control power from 
anywhere in the world with a click of a mouse.  iB-30 also supports Telnet for text commands, as well 
as Dataprobe’s Exchange Protocol (DxP) for interfacing to a variety of Dataprobe products and 
custom software development.   
 

Note:

 

iB-30 – iBoot-G2 reference

 

In some parts of the manual references and drawings are made to the iBoot-G2 which is the core 
network interface and controller board used in the iB-30. 
 

Uses for iBoot 

• 

Remote reboot of any device, 
routers, servers, kiosks, etc.  The 
device to be rebooted need not be 
network attached. 

• 

Secure sensitive devices by keeping 
them powered off when not in use.  
This prevents hackers from seeing 
them at all times. 

• 

Power down equipment when not 
needed for power savings and to 
save on wear and tear. 

• 

Power up alert devices like sirens, lamps, messages; or control environmental system like 
heaters, coolers pumps, etc. 

 

Multiple Control Options 

 
In addition to the Web control capabilities, iB-30 features several other means to operate 
automatically or under computer control.   
 
AutoPing: The AutoPing feature allows iB-30 to automatically detect failed equipment and perform a 
timed reboot or other power control function (like turning on an indicator or siren).  You set 1 or 2 IP 
addresses to be periodically pinged.  When iB-30 no longer detects a response from the address(es), 
the programmed power control function is actuated. 
 
Telnet:  iBoot’s Command Line Interface (CLI) allows direct command and setup through Telnet. 
 
Dataprobe Exchange Protocol:  iB-30 supports Dataprobe Exchange Protocol (DxP)  This protocol 
allows Dataprobe products to communicate across networks, and allows developers to design custom 
applications to integrate iB-30 into custom applications.  For more information about DxP, contact 
Dataprobe Applications Engineering and Support.

Содержание iBoot-30A

Страница 1: ...ntents 1 Important Safety Instructions 2 General Description 3 Hardware Installation 4 Initial Configuration 5 Web Browser Operation 7 Web Setup 8 Command Line Interface 13 Firmware Upgrades 17 Troubl...

Страница 2: ...to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this...

Страница 3: ...devices by keeping them powered off when not in use This prevents hackers from seeing them at all times Power down equipment when not needed for power savings and to save on wear and tear Power up ale...

Страница 4: ...ections enter the unit by selecting one or two of the larger knockouts similar to those used for the above network connection and installing the larger cable clamps All AC connections are made on the...

Страница 5: ...ess Make sure you have physical access to the iB 30 before attempting to set the IP Address The Setup Utility will only work with iBoots on the same local subnets as the PC Once the iB 30 Setup Utilit...

Страница 6: ...via the Set up Page 3 CLI Telnet iB 30 comes with factory installed IP address 192 168 1 254 If you network has a DHCP server it will automatically assign an IP address to iB 30 the first time it is c...

Страница 7: ...ck on the appropriate button During power cycling the Power Status bar will indicate the temporary status with a blue background Once the cycle is complete the status bar will revert to its original c...

Страница 8: ...Telnet and reboot the unit Web Setup iB 30 setup section consists of several pages Access any page via the buttons on the left of the page Each time a setting is changed click on the Save button for t...

Страница 9: ...30 Upon Clicking Reboot the Googbye page is displayed with a link to re login AutoPing Settings The AutoPing feature allows iB 30 to automatically detect failed equipment and perform a timed reboot or...

Страница 10: ...remain so until changed via the web telnet DxP etc Power Off Follow Upon triggering iB 30 will power off When the ping response returns iB 30 will power on Power Cycle Upon triggering iB 30 will cycle...

Страница 11: ...e zone relative to GMT Once the time server is active scheduled events can occur Up to eight independent scheduled events can be programmed Date Set the initial date for the event The format for the d...

Страница 12: ...used the main screen will not have a link to Setup The Administrator Password allows access to both the Main Screen and the Setup Screen Passwords can be up to 20 characters long and are case sensitiv...

Страница 13: ...y Default CONTROL COMMANDS These commands are used to monitor and control the outlet set outlet on off cycle This command controls the outlet get outlet This command returns the current status of the...

Страница 14: ...The CLI will protect against all 3 from being set to 0 9100 set timeout 0 999 This command sets the automatic network timeout in minutes 2 AUTOPING COMMANDS These commands require a reboot before the...

Страница 15: ...es no This command enables or disables the use of the time server and scheduled events No get time Displays the current time and time server Current Time 16 10 41 01 27 2010 Server 64 90 182 55 set ev...

Страница 16: ...iBoot 30A Page 16 iBoot 30a_v101118e prompt will remain the active prompt until the iB 30 has been rebooted...

Страница 17: ...lable at the link above If the iBoot you would like to upgrade is not visible in the list box either Select Device Discover from the menu to locate iB 30 units on the local network or Select Device Ad...

Страница 18: ...nal blocks or AC wiring when the unit is connected to the AC power source Use the pushbutton as follows Action Result Momentary Soft Reset Will not change outlet status 5 Seconds push Reset to Factory...

Страница 19: ...Max at 210 240 VAC Compliance CE Directives 89 336 EEC 92 31 EEC and 93 68 EEC EN 60950 3rd Edition EN 55022 1998 Class B FCC Part 15 Class B Network Dual 10 100 Unshielded Twisted Pair Ethernet Jacks...

Страница 20: ...chnical Service at 201 934 5111 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipm...

Отзывы: