iBoot-30a_v101118e
Note: All of the AutoPing Settings require a reboot of the iB-30, after clicking Save. A Reboot button
will appear at the bottom of the page. The new settings will not take effect until the unit is
rebooted. Reboot will not affect the power position of the iB-30. Upon Clicking Reboot, the
Googbye page is displayed with a link to re-login.
Event Scheduling
iB-30 can schedule up to eight reoccurring power
events. Set the starting date and time, plus the
action to be taken and any repeat cycle for each.
To enable the time scheduling function:
Enter an accessible Network Time Server and
check the Enable box. A list of public time
servers is available at
http://www.ntp.org/
Set
your local time zone relative to GMT.
Once the time server is active, scheduled events
can occur. Up to eight independent scheduled
events can be programmed.
Date: Set the initial date for the event. The
format for the date is mm/dd/yyyy.
Time: Set the initial time for the event. The format for the time is hh:mm:ss with hours in 24 hour
format.
Repeat: Set the increment of the repeat, if desired. Set the number from 0 to 999 and either Days,
Minutes or Seconds.
Action: Set the event Action; On, Off or Cycle.
Click Save to save the current settings. Click Clear to delete any current schedule.
Note: All of the Schedule Settings require a reboot of the iB-30, after clicking Save. A Reboot button
will appear at the bottom of the page. The new settings will not take effect until the unit is
rebooted. Reboot will not affect the power position of the iB-30. Upon Clicking Reboot, the
Googbye page is displayed with a link to re-login.
Schedule Setup Page