ENTER/EXIT PROGRAMMING MODE
USB-COM INTERFACES
8
QUICKSCAN™ I QD2200
Disable Character
Specifies the value of the host command used to disable the scanner.
ASCII characters or any hex value from 0 to 0xFF can be selected. See
for more detailed programming instructions.
Enable Character
Specifies the value of the host command used to enable the scanner.
ASCII characters or any hex value from 0 to 0xFF can be selected. See
for more detailed programming instructions
Setting to previously defined characters such as XON, XOFF, or host com
-
mands conflicts with normal operation of these characters.
Select Disable Character Setting
$CR2DC
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
0x44 = Disable Character is ‘D’
Setting to previously defined characters such as XON, XOFF, or host com
-
mands conflicts with normal operation of these characters.
Select Enable Character Setting
$CR2EC
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
0x45 = Enable Character is ‘E’
Содержание Quickscan QD2200
Страница 1: ...L Quickscan I QD2200 PRODUCT REFERENCE GUIDE General Purpose Corded Handheld Linear Bar Code Reader...
Страница 13: ...TECHNICAL SUPPORT PRODUCT REFERENCE GUIDE xiii NOTES...
Страница 219: ...SAMPLE BARCODES PRODUCT REFERENCE GUIDE 189 Interleaved 2 of 5 Code 32 Codabar Code 93 Code 11 12345678901231...
Страница 222: ...KEYPAD 192 QUICKSCAN I QD2200 1 2 3 4 5 6 7 8 9...