INTRODUCTION
37
2
Learn (Function 4)
Once entered, the imager starts a procedure to automatically detect and recognize codes
which are presented to it.
The Learn LED will blink until the procedure is completed.
The Learn procedure ends when the Image Processing and Decoding parameters are
successfully saved in the reader memory, the Learn LED will remain on continuously and
Matrix 450™ emits 3 high pitched beeps.
If the calibration cannot be reached after a timeout of about 3 (three) minutes, Matrix 450™ will
exit without saving the parameters to memory, the Learn LED will not remain on continuously
but it will just stop blinking. In this case Matrix 450™ emits a long low pitched beep.
2.6 MODEL DESCRIPTION
The Matrix 450™ reader is available in different versions according to the following
characteristics:
MATRIX 450 XXX-0X0
Illuminator s
0 = BS (Base, No Illuminator)
Lens
0 = C -Mount (No Lens)
Sensor Size
8 = 5.0 Megapixels
(2448x2050)
Interface
3 = Gigabit Ethernet
(GIGE)