READING FEATURES
111
7
Matrix 450™ + LNS-1225
CONDITIONS:
Hardware Settings
Code Symbology
Code 128
Code Resolution
0.51 mm (20 mils)
Focal Length
25 mm
Aperture Stop
F/5.6
Focus Distance
2.500 mm (98.4 inches)
PPI 70
Tilt Angle
45°
Skew Angle
15°
Lighting System
LT-030
LT-031
LT-032
Software Parameters
Exposure Time (×10µs)
25
25
38
Max code moving speed
1.8 m/s
1.8 m/s
1.2 m/s
Gain 8
16
19
LT-03x Lighting Mode
Very High Power Strobed or Continuous High Power
Minimum Code Height (mm)
5
Code 128 Narrow Margins
Enabled
Image Processing Mode
Advanced Code Setting
Reading Distance
Horizontal Reading Width
Code 1D 0.51 mm (20 mils)
(in)
(cm)
30
20
0
10
50
40
-30
-20
-10
-50
-40
12
8
0
4
16
-12
-8
-4
-16
190 210
230
250 260
310
300
290
280
270
240
220
200
180
72 84
104
88
92
96
100
108 112 116 120
76 80