INSTALLATION
49
3
Matrix 450™ is able to decode code labels at a variety of angles; however significant angular
distortion may degrade reading performance.
When mounting Matrix 450™, take into consideration these
ideal
label position angles:
Pitch
or Skew 10° to 20° and Tilt 0°
.
Note:
Since Matrix 450™ is omni-directional on the code plane, the Pitch and Skew angles
have the same significance with respect to the code plane. However in some advanced code
reading applications performance can be improved by modifying the Skew angle.
Follow the suggestions below for the best orientation:
The
Pitch and Skew
angles are represented by the values
P
and
S
in Figure 25 and in Figure
26. Position the reader in order to avoid the direct reflection of the light emitted by the Matrix
450™ reader; it is advised to
assure at least 10°
for one of these angles. In some cases, such
as low contrast or low illumination, it can be useful to use a
Pitch or Skew
angle = 0°.
P
Minimize
Figure 25 - Pitch angle
S
Assure at least 10°
Figure 26 - Skew angle
The
Tilt
angle is represented by the value
T
in Figure 27. Matrix 450™ can read labels with
any tilt angle.
T
Minimize
Figure 27 - Tilt angle
See par. 7.1 and 7.2 for FOV vs. Reading Distance considerations.