Scanning Features
References
Product Reference Guide
269
Phase Off Event:
Specifies whether the reading phase is closed on a timeout or phase off event.
The following selections are available:
•
Trigger Stop: the reading phase ends when the serial stop character (or string) is received.
Timeout is disabled.
•
Timeout: the reading phase ends when the timeout is expired. Serial stop character (or
string) is ignored.
•
Trigger Stop - Timeout: the reading phase ends when the first event occured.
Timeout (Scanning Active Time option):
Specifies the maximum duration for the reading
phase. Selections: from 1 to 255 seconds in 1 second increments.
Automatic Mode
In Automatic mode, the scanner is continuously scanning. When a label enters the reading zone
and is decoded, no more decodes and reading phases are allowed until the label has left the
reading area. In order to guarantee identification of the code in the reading zone, a threshold
specifies the number of scans after the successful decode that the scanner will wait before
rearming the reading phase. The transmission of the decoded label depends on the
configuration of the Transmission Mode parameter.
Automatic/Trigger Object Sense
Automatic/TOS mode is the same as Automatic mode but with the illumination system
normally off*. As an object or bar code enters the reading area, illumination is turned ON.
Illumination will return to the Presentation Illumination Control setting as the reading phase is
closed (see Automatic Mode above).
*Default. The illumination can be programmed for several different operation states
(off, dim or on) while the reading phase is not active. See
"Presentation Illumination
Control" on page 86
.
Digital Output
Output Activation:
Digital Output can be set to be Activated/Deactivated when specified events occur.
Line State:
Selects whether the line is Active Low or Active High.
Activation Event:
Selects the event the line is activated on. Selectable events are Disabled, Good
Read, No Read, Right Code, Wrong Code. Right Code and Wrong Code are available only if
Code Verifier functionality is enabled.
Deactivation Event:
Selects the event the line is deactivated on. Selectable events are Disabled,
Timeout, Reading Phase On.
Deactivation Timeout:
Related to the previous parameter, this feature sets the deactivation
timeout for the output.
Содержание Gryphon I GFS4400
Страница 10: ...Contents 8 Gryphon I GFS4400 NOTES...
Страница 22: ...Setup Custom Configuration Settings 20 Gryphon I GFS4400 NOTES...
Страница 26: ...Enter Exit Programming Mode 24 Gryphon I GFS4400 NOTES...
Страница 48: ...Enter Exit Programming Mode USB Keyboard Settings 46 Gryphon I GFS4400 NOTES...
Страница 52: ...USB OEM Interface 50 Gryphon I GFS4400 NOTES...
Страница 70: ...Enter Exit Programming Mode Data Format 68 Gryphon I GFS4400 NOTES...
Страница 218: ...2D Symbologies 216 Gryphon I GFS4400 NOTES...
Страница 244: ...Software Configuration Strings 242 Gryphon I GFS4400 NOTES...
Страница 276: ...References Scanning Features 274 Gryphon I GFS4400 NOTES...
Страница 286: ...Technical Specifications 284 Gryphon I GFS4400 NOTES...
Страница 290: ...Aimer Calibration 288 Gryphon I GFS4400 NOTES...
Страница 302: ...Standard Defaults 300 Gryphon I GFS4400 NOTES...
Страница 304: ...Sample Bar Codes 302 Gryphon I GFS4400 1D Bar Codes continued Code 32 Codabar Code 93 Code 11...
Страница 308: ...306 Gryphon I GFS4400 A B C D E F...
Страница 310: ...308 Gryphon I GFS4400 NOTES...
Страница 320: ...318 Gryphon I GFS4400 NOTES...
Страница 321: ...Product Reference Guide 319 NOTES...
Страница 322: ...320 Gryphon I GFS4400 NOTES...