Reading Parameters
References
Product Reference Guide
267
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a good
read. The good read LED on time can be set within a range of 10 milliseconds to 2,550
milliseconds (0.001 to 2.55 seconds) in 100ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good read
LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 10 (setting is in 100ms increments). Pad the result with lead-
ing zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.
3. Go to
page 79
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter
Programming Mode.
4. Scan the bar code: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in
Appendix E, Keypad
representing the
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See
Table 36
for some examples of how to set this feature.
Table 36. Good Read LED Duration Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Good Read LED
stays on until next
trigger pull (00)
20ms
150ms
2550ms (2.55 sec.)
2
Divide by 10 (and pad with
leading zeroes)
000
002
015
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT GOOD READ LED DURATION SETTING
5
Scan Three Characters From
Appendix E, Keypad
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘2’
‘0’, ‘1’ and ‘5’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание Gryphon I GFS4400
Страница 10: ...Contents 8 Gryphon I GFS4400 NOTES...
Страница 22: ...Setup Custom Configuration Settings 20 Gryphon I GFS4400 NOTES...
Страница 26: ...Enter Exit Programming Mode 24 Gryphon I GFS4400 NOTES...
Страница 48: ...Enter Exit Programming Mode USB Keyboard Settings 46 Gryphon I GFS4400 NOTES...
Страница 52: ...USB OEM Interface 50 Gryphon I GFS4400 NOTES...
Страница 70: ...Enter Exit Programming Mode Data Format 68 Gryphon I GFS4400 NOTES...
Страница 218: ...2D Symbologies 216 Gryphon I GFS4400 NOTES...
Страница 244: ...Software Configuration Strings 242 Gryphon I GFS4400 NOTES...
Страница 276: ...References Scanning Features 274 Gryphon I GFS4400 NOTES...
Страница 286: ...Technical Specifications 284 Gryphon I GFS4400 NOTES...
Страница 290: ...Aimer Calibration 288 Gryphon I GFS4400 NOTES...
Страница 302: ...Standard Defaults 300 Gryphon I GFS4400 NOTES...
Страница 304: ...Sample Bar Codes 302 Gryphon I GFS4400 1D Bar Codes continued Code 32 Codabar Code 93 Code 11...
Страница 308: ...306 Gryphon I GFS4400 A B C D E F...
Страница 310: ...308 Gryphon I GFS4400 NOTES...
Страница 320: ...318 Gryphon I GFS4400 NOTES...
Страница 321: ...Product Reference Guide 319 NOTES...
Страница 322: ...320 Gryphon I GFS4400 NOTES...