DS6400 REFERENCE MANUAL
66
7
7.1.2 Multidata Network
In this layout, one master and up to 7 DS6400 slave readers have their own P.S. and
therefore multiple reading phases. Each P.S. is connected through a CBX100, which in turn
is connected to its relative scanner through a CAB-Sxx cable.
Typically these systems are reading stations which are located relatively far away from each
other and are therefore usually each powered separately. In this case, the Lonworks network
must use CAB-611x "no power" cables.
The master sends all the individual messages collected from the Lonworks interface as well
as its own to the Local Host through its CBX100.
* Each P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
Figure 86
– Multidata Network
CBX100
Local Host
PG6000
P.S.*
CAB-Sxx
CAB-611x
CAB-611x
CAB-611x
CAB-Sxx
CAB-Sxx
CAB-Sxx
BT-6000
BT
-6000
Slave 3
P.S.*
P.S.*
P.S.*
Slave 2
Slave 1
Master
PG6000
PG6000
PG6000