READING FEATURES
101
9
Minimum Code Height for ACR Reading (mm)
45°
30°
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
0.25
8
9
11 13 15 17
5
7
8
10 11 13
0.30
8
10 12 14 16 18
6
7
9
10 12 13
Code 128
– GS1-128
0.33
9
11 13 14 16 18
6
8
9
11 12 14
Code Resolution
0.38
10 11 13 15 17 19
7
8
10 11 13 14
(mm)
0.50
12 13 15 17 19 21
8
9
11 12 14 15
0.72
16 17 19 21 22 24 10 11 13 14 16 17
1.00
22 23 24 25 27 29 13 14 15 17 18 20
Table 3
Minimum Code Height for ACR Reading (mm)
45°
30°
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
0.25
8
9
11 13 15 17
5
7
8
10 11 13
0.30
9
10 12 14 16 18
6
7
9
10 12 13
Codabar
0.33
9
11 13 14 16 18
6
8
9
11 12 14
Code Resolution
0.38
10 11 13 15 17 19
7
8
10 11 13 14
(mm)
0.50
13 14 15 17 19 21
8
9
11 12 14 15
0.72
17 18 19 21 22 24 11 12 13 14 16 17
1.00
23 24 25 26 27 29 14 15 16 17 18 20
Ratio 3:1; Interdigit = Module Size
Table 4
Minimum Code Height for ACR Reading (mm)
45°
30°
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
0.25
7
9
10 12 14 16
5
6
8
9
11 12
0.30
8
9
11 13 15 17
6
7
8
10 11 13
EAN 8-13, UPC-A
0.33
9
10 11 13 15 17
6
7
9
10 12 13
Code Resolution
0.38
10 11 12 14 16 18
7
7
9
10 12 13
(mm)
0.50
12 13 14 15 17 19
8
9
10 11 13 14
0.72
16 17 18 19 20 22 10 11 12 13 14 16
1.00
22 23 24 24 25 26 13 14 15 16 16 18
Table 5