INSTALLATION
20
AREX™ 401
INSTALLATION ENVIRONMENT
Control rack
The control rack must be installed in a suitable environment in order to allow proper air
flow and correct housing of the cables.
The control rack uses a forced air cooling system: an adequate air flow is necessary to
guarantee its correct cooling. Install the control rack so that air flow is not obstructed.
Moreover, do not install it near a heat source.
Clean the air filter when it is dirty. If the air filter is dirty, insufficient air-flow might not
ensure correct cooling and might stop the marking operation. Clean or replace the air
filter periodically.
≥
300mm
Figure 13: Control rack installation environment
CAUTION: If not enough space is provided, the temperature inside the con-
trol rack could rise, causing temperature error.
CAUTION: DO NOT place heavy objects on top of the control rack!
NOTE: The control rack IP rating is IP31 in horizontal position, otherwise
IP30.
Содержание AREX 401
Страница 1: ...AREX 401 USER MANUAL InfraRed Fiber Laser Marker...
Страница 66: ...SET UP 58 AREX 401 Figure 51 Connecting the monitor NOTE Minimum monitor resolution 800 x 600 VGA standard...
Страница 113: ...SLO INTEGRATION EXAMPLE USER MANUAL 105 SLO INTEGRATION EXAMPLE...
Страница 140: ...RECOVER THE LASER MARKER 132 AREX 401 Press FINISH to continue Press YES to continue...
Страница 141: ...HOW TO RECOVER THE LASER MARKER USER MANUAL 133 Wait for disks restoring The system will restart automatically...
Страница 145: ...USER MANUAL 137 APPENDIX G MECHANICAL DRAWINGS...
Страница 146: ...MECHANICAL DRAWINGS 138 AREX 401 CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings...
Страница 147: ...SCAN HEAD USER MANUAL 139 SCAN HEAD NOTE Please refer to Datalogic website for detailed drawings...