TECHNICAL SPECIFICATIONS
34
AREX™ 401
Table 5: X1 - Command Box connector pinout
(*) refers to Lighter™ user's manual “Setting I/O parameters” paragraph to set the signal properties
(**) refers to Lighter™ user's manual
(***) see “Input/Output specifications” on page 41
X1.16
VIN_EXT
Input power
supply
External reference input power supply voltage for PNP output type
configuration:
- NOT CONNECTED or GND: sets all digital outputs to NPN (default)
- 10÷28V DC sets all digital outputs to PNP
X1.17
END
Digital Output
PNP/NPN
configurable
This signal is used to know if the marking process is finished:
- ON at the end of marking process
X1.18
POWER_ON
Digital Output
PNP/NPN
configurable
This signal is used to know if the laser marker is already warmed up:
- ON when the laser is in STAND_BY or READY state
X1.19
GND
Ground
Ground reference
X1.20
SYSTEM_ALARM
Digital Output
PNP/NPN
configurable
This signal is used to know if the laser marker is in booting up state
or in error state:
- ON during BOOTING UP
- ON in case of system error
X1.21
GND
Ground
Ground reference
X1.22
ENABLE_OUT
Digital Output
PNP/NPN
configurable
This signal is used to know if the laser marker is ready to emit laser
radiation:
- ON when the laser marker is in READY state
X1.23
SW_READY*
Digital Output
PNP/NPN
configurable
Depending on the configuration this signal can be used in different
ways:
- COMPATIBILITY: ON when a document or a sequence is running in
AUTO MODE** or WORK MODE** independently from the laser
marker state. The signal is ON regardless of whether the laser
marker is ready to start a new marking
- STANDARD: ON when a document or a sequence is running in AUTO
MODE** or WORK MODE** and the laser marker state is READY. The
signal is ON regardless of whether the laser marker is ready to start a
new marking
- READY TO MARK: ON only when a document or a sequence is run-
ning in AUTO MODE** or WORK MODE** and the laser marker state is
READY. The signal is ON only if the laser marker is ready to accept a
new START_MARKING event (loading/spooling already executed)
This signal can also be driven using Lighter™ Script engine
"IoPort.setReady (true)" function
X1.24
GND
Ground
Ground reference
X1.25
GND
Ground
Ground reference
PIN
SIGNAL
TYPE***
DESCRIPTION
Содержание AREX 401
Страница 1: ...AREX 401 USER MANUAL InfraRed Fiber Laser Marker...
Страница 66: ...SET UP 58 AREX 401 Figure 51 Connecting the monitor NOTE Minimum monitor resolution 800 x 600 VGA standard...
Страница 113: ...SLO INTEGRATION EXAMPLE USER MANUAL 105 SLO INTEGRATION EXAMPLE...
Страница 140: ...RECOVER THE LASER MARKER 132 AREX 401 Press FINISH to continue Press YES to continue...
Страница 141: ...HOW TO RECOVER THE LASER MARKER USER MANUAL 133 Wait for disks restoring The system will restart automatically...
Страница 145: ...USER MANUAL 137 APPENDIX G MECHANICAL DRAWINGS...
Страница 146: ...MECHANICAL DRAWINGS 138 AREX 401 CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings...
Страница 147: ...SCAN HEAD USER MANUAL 139 SCAN HEAD NOTE Please refer to Datalogic website for detailed drawings...