DKG-317 User Manual V-01.19
(01.10.2009)
- 6 -
3. DISPLAYS
3.1 Led Displays
The unit has 20 LEDs:
-Group_1:
Warnings and alarms: This group indicates the existence of abnormal conditions
encountered during operation.
-Group_2:
Unit: This group indicates the unit of the value displayed in the bottom display.
Function
Color
Description
SERVICE REQUEST
Red
Engine periodic maintenance request indicator. It
turns on when the preset engine hours or time
duration after previous service has elapsed.
ALARM GROUP
Red
If a fault condition resulting to the engine shutdown
has occurred, the related alarm led turns on steadily.
If a warning condition has occurred, the related led
flashes. The alarms work on a first occurring basis.
The occurrence of a fault will disable other faults of
lower or equal priority.
UNIT GROUP
Red
This group indicates the unit of the value displayed in
the bottom display. When the engine is running the
unit displays the genset frequency, otherwise it
displays the battery voltage. Different values may be
scrolled by pressing the
MENU
key.