DKG-209 User Manual V-29
(20.08.2013)
- 51 -
Alternator voltage:
0 to 300 V-AC Phase to Neutral (0 to 520 V-AC Phase to Phase)
Alternator frequency:
0-100 Hz.
Mains voltage:
0 to 300 V-AC Phase to Neutral (0 to 520 V-AC Phase to Phase)
Mains frequency:
0-100 Hz.
Current input range:
0.1
– 6 A AC
Voltage burden:
< 0.1VA per phase
Current burden:
< 0.5VA per phase @ 5A AC
Accuracy:
Voltage:
1.0%+1digit
Current:
1.0%+1 digit
Frequency:
0.5%+1 digit
Power(kW,kVAr):
2.0%+12digit
Power factor:
2.0%+1 digit
DC Supply range:
9.0 V
DC
to 16.0 V
DC
Cranking dropouts:
survives 0 V for 100ms
Typical stand-by current consumption:
100 mA
DC
.
Maximum current consumption:
200 mA
DC
.
Generator/mains contactor outputs:
16 A @ 250 V
AC
.
DC outputs:
1A @ 28 V
DC
. protected semiconductor outputs
Charge alternator excitation:
min 2W.
Current inputs:
from current transformers, .../5A. Max load 0.7VA per phase.
Digital inputs:
input voltage 0 - 30 V
DC
. Internally connected to battery positive via 47
’000 ohm resistor.
Analog inputs:
Resistor input 0 to 5000 ohms connected to the battery negative. Sources 5 mA when
closed to battery negative.
Measurement category:
CAT II
Air category:
Pollution degree II
Communication port:
Logic level. 9600 bauds, no parity, 1 stop bit.
Operating temperature range:
-20
C to +70
C (-4
ºF to +158 ºF)
Storage temperature range:
-40
C to +80
C (-40
ºF to +176 ºF)
Maximum humidity:
95%, non-condensing
Dimensions:
133x107x39mm (WxHxD)
Panel Cut-out dimensions:
117 x 87mm minimum.
Weight:
200 g (approx.)
Case material:
High temperature, self extinguishing ABS/PC (UL94-V0)
IP protection:
IP65 from front panel, IP30 from the rear
16. TECHNICAL SPECIFICATIONS