D-700 MK3 User Manual Firmware V-16.8
- 136 -
Parameter Definition
Unit
Min
Max
Factory
Set
Description
Sender Curve-1 ohm
ohms
0
5000
Point-1 ohm value
Sender Curve-1 value
x
0
10000
Point-1 reading
Sender Curve-2 ohm
ohms
0
5000
Point-2 ohm value
Sender Curve-2 value
x
0
10000
Point-2 reading
Sender Curve-3 ohm
ohms
0
5000
Point-3 ohm value
Sender Curve-3 value
x
0
10000
Point-3 reading
Sender Curve-4 ohm
ohms
0
5000
Point-4 ohm value
Sender Curve-4 value
x
0
10000
Point-4 reading
Sender Curve-5 ohm
ohms
0
5000
Point-5 ohm value
Sender Curve-5 value
x
0
10000
Point-5 reading
Sender Curve-6 ohm
ohms
0
5000
Point-6 ohm value
Sender Curve-6 value
x
0
10000
Point-6 reading
Sender Curve-7 ohm
ohms
0
5000
Point-7 ohm value
Sender Curve-7 value
x
0
10000
Point-7 reading
Sender Curve-8 ohm
ohms
0
5000
Point-8 ohm value
Sender Curve-8 value
x
0
10000
Point-8 reading
Sender Curve-9 ohm
ohms
0
5000
Point-9 ohm value
Sender Curve-9 value
x
0
10000
Point-9 reading
Sender Curve-10 ohm
ohms
0
5000
Point-10 ohm value
Sender Curve-10 value
x
0
10000
Point-10 reading
Sender Curve-11 ohm
ohms
0
5000
Point-11 ohm value
Sender Curve-11 value
x
0
10000
Point-11 reading
Sender Curve-12 ohm
ohms
0
5000
Point-12 ohm value
Sender Curve-12 value
x
0
10000
Point-12 reading
Sender Curve-13 ohm
ohms
0
5000
Point-13 ohm value
Sender Curve-13 value
x
0
10000
Point-13 reading
Sender Curve-14 ohm
ohms
0
5000
Point-14 ohm value
Sender Curve-14 value
x
0
10000
Point-14 reading
Sender Curve-15 ohm
ohms
0
5000
Point-15 ohm value
Sender Curve-15 value
x
0
10000
Point-15 reading
Sender Curve-16 ohm
ohms
0
5000
Point-16 ohm value
Sender Curve-16 value
x
0
10000
Point-16 reading
Sender Name
-
-
-
If the sender type parameter is set to
zero (not used), this string is used as
sender name while displaying the
sender reading.
Sender Low Fault String
-
-
-
If the sender type parameter is set to
zero (not used), this string is used as
sender low value fault in the alarm
display.
Sender High Fault String
-
-
-
If the sender type parameter is set to
zero (not used), this string is used as
sender high value fault in the alarm
display.
Содержание D-700 MK3
Страница 50: ...D 700 MK3 User Manual Firmware V 16 8 50 5 3 3 PHASE 3 WIRE DELTA 5 2 3 PHASE 4 WIRE STAR...
Страница 51: ...D 700 MK3 User Manual Firmware V 16 8 51 5 4 3 PHASE 4 WIRE DELTA 5 5 3 PHASE 3 WIRE DELTA 2 CT L1 L2...
Страница 53: ...D 700 MK3 User Manual Firmware V 16 8 53 5 9 1 PHASE 2 WIRE 5 8 2 PHASE 3 WIRE DELTA 2 CTs L1 L3...
Страница 63: ...D 700 MK3 User Manual Firmware V 16 8 63 7 1 GENSET SYNCHRONIZATION FUNCTIONALITY 7 CONNECTION DIAGRAMS...
Страница 64: ...D 700 MK3 User Manual Firmware V 16 8 64 7 2 MAINS SYNCHRONIZATION FUNCTIONALITY...
Страница 65: ...D 700 MK3 User Manual Firmware V 16 8 65 7 3 SINGLE GENSET PARALLEL WITH MAINS FUNCT...
Страница 66: ...D 700 MK3 User Manual Firmware V 16 8 66 7 4 DC GENSET FUNCTIONALITY...
Страница 67: ...D 700 MK3 User Manual Firmware V 16 8 67 7 5 AMF FUNCTIONALITY...
Страница 68: ...D 700 MK3 User Manual Firmware V 16 8 68 7 6 ATS FUNCTIONALITY...
Страница 69: ...D 700 MK3 User Manual Firmware V 16 8 69 7 7 REMOTE START FUNCTIONALITY...
Страница 70: ...D 700 MK3 User Manual Firmware V 16 8 70 7 8 ENGINE CONTROL FUNCTIONALITY...
Страница 71: ...D 700 MK3 User Manual Firmware V 16 8 71 7 9 REMOTE DISPLAY PANEL FUNCTIONALITY...
Страница 83: ...D 700 MK3 User Manual Firmware V 16 8 83...