Manual Datafox Evo 4.6 FleKey
Page 83
Date: 14.09.2021 V 04.03.17.XX
Table
Action
(list of all workable actions in the access control system; an action group, i.e. all ac-
tions with the same action number, can switch several relays)
Name
Data type
Length
Description
ID
Number
(int)
4
Action number, it can occur several times due to several actions that have to
be worked through.
RefReader
Number
(int)
4
Module (door module or master) on which an output(relay) is switched.
PortOut
Number
(int)
1
Indicates the number of the output on the module.
Elapse
Number
(int)
3
The duration of the switching of the relay (0 = permanently). Unit 200 ms
RefTime
Number
(int)
4
The time model indicates when the output may be switched. (0 = not used)
This is a function to switch relays directly via time (table)
Please not mix this function with the normal access actions.
!!! By a time-
table setting “1234567 00:00-23:59” is the relay permanent on.