![Datafox Evo 4.6 FleKey Скачать руководство пользователя страница 121](http://html.mh-extra.com/html/datafox/evo-4-6-flekey/evo-4-6-flekey_manual_511640121.webp)
Manual Datafox Evo 4.6 FleKey
Page 114
Date: 14.09.2021 V 04.03.17.XX
5.8.8. Calculation for the power supply of Access modules
When using Datafox access readers or door modules, the necessary cable cross-section has to be
calculated before setting up an RS485 network for access control. The voltage drop in the whole
bus must not exceed 4 V. Please note that if you use a Datafox device power supply unit as voltage
source, 16 modules at most (8 in the RS485 bus and 8 via RS232 stub line) can be fed.
Maximum power consumption of the single modules:
TS-TMR33-TR
56,5 mA
16 V max. 8 V min.DC
TS-TMR33-TM
156,0 mA
16 V max. 8 V min.DC
TS-TMR33-TMR
180,0 mA
16 V max. 8 V min.DC
EVO-reader
250,0 mA
24 V max. 9 V min.DC
PHG-reader
250,0 mA
24 V max. 9 V min.DC
The result is a permissible maximum power consumption per Datafox power supply unit of (8 x
180.0 mA + 8 x 56.5 mA) 1.9 A. In order to assure this, you can calculate the necessary cross-sec-
tion for a given cable length or the permissible maximum cable length for a given cable cross-sec-
tion.
!
Caution:
Before setting up and commissioning a ZK-network, the calculation
has to be done by a person qualified in this field.
The cable cross-section is calculated as follows:
The following applies for 12 V voltage supply:
Uv
= voltage drop. 4V at most.
4
V
TMR33
Uv
= voltage drop. 4V at most.
3
V
PHG
and Reder
EVO-ZK
Uv
is calculated from the supply voltage minus the minimum voltage for the reader.
Thus, the equation for calculating the maximum cable length for a given cable cross-section
is:
v
U
k
l
I
Q
2
I
U
k
Q
l
v
2
Q
= wire size in mm
2
I
= current
l
= wire length in m
k
= Conductivity for copper 56
2
mm
m
Содержание Evo 4.6 FleKey
Страница 1: ...Manual Datafox Evo 4 6 FleKey Flexible data collection with method ...
Страница 62: ...Manual Datafox Evo 4 6 FleKey Page 55 Date 14 09 2021 V 04 03 17 XX 5 6 3 9 RS 485 bus for access control ...
Страница 95: ...Manual Datafox Evo 4 6 FleKey Page 88 Date 14 09 2021 V 04 03 17 XX Titan EM4450 Mifare Ultralight ...
Страница 167: ...Manual Datafox Evo 4 6 FleKey Page 160 Date 14 09 2021 V 04 03 17 XX ...