background image

© 2011 Datacom Systems Inc

Datacom Systems Inc

Access Your Network

TM

May 2011

guide

VS-1200-S Series
Data Access Switch

541-0133-U-B.00

USER

VS-1200-S Series Data Access Switch

Содержание VS-1200-S Series

Страница 1: ... 2011 Datacom Systems Inc Datacom Systems Inc Access Your Network TM May 2011 guide VS 1200 S Series Data Access Switch 541 0133 U B 00 USER VS 1200 S Series Data Access Switch ...

Страница 2: ......

Страница 3: ... input or output ports Aggregation offers a complete view of the traffic and easily lets security and analysis tools collect all the data they need expanding network visibility The Datacom System VERSAstream VS 1200 S Data Access Switch series supports your ability to specifically apply your peripheral network tools to the analysis requirements and adapt with your ever changing network ...

Страница 4: ... claim to these trademarks While every precaution has been taken in the preparation of this document the publisher and the author assume no responsibility for errors or omissions or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it In no event shall the publisher and the author be liable for any loss of pr...

Страница 5: ... 15 1 VS 1200 S Series Front Panels 16 2 Front Panel Description 16 Power 16 Any to Any Ports 17 Management Port 17 3 Rear Panel Description 17 Serial DB9 17 Power Switch SFP series 17 Rear Label BT series 18 Rear Labeling SFP series 18 Input Power Section 4 Initial Configuration 19 19 1 Command Line Interface CLI 19 Basic Functionality 20 Password Recovery 20 Basic Commands Read Only Access 20 HE...

Страница 6: ...UPERUSER SE V3 SU 31 2 SERIAL Port Configuration DB9 31 HyperTerminal 32 3 MANAGEMENT Port Configuration RJ45 32 HyperTerminal 33 TELNET 33 4 IP Address Configuration 33 IP Address Configuration with HyperTerminal 37 IP Address Configuration with TELNET 41 5 Exercise CLI Setting Ports 45 6 Management Connection RJ45 45 TELNET 46 SSH 48 7 SNMP Configuration 49 8 Small Form Factor Plug Module 49 Int...

Страница 7: ...uration example Section 8 Customer Service 61 61 1 Internet 61 2 Warranty 61 3 Limits of Liability Section 9 Appendix A Agent Capabilities MIB 63 Section 10 Appendix B Power Supply MIB 71 Section 11 Appendix C Structure of Management Information MIB 83 Section 12 Appendix D FLASHutils 89 ...

Страница 8: ......

Страница 9: ...technology described and Datacom Systems Inc retains all rights with respect to the technology described herein If applicable you may return the product to the place of purchase for a full refund 1 3 Trademark Attribution Access Your Network DS3 ACTIVEtap DS3switch ETHERNETtap Empowering Network Professionals FDDIswitch FIBERsplitter FIBERswitch FIBERSWITCH system FLOWcontrol GIGABITswitch INSERTs...

Страница 10: ...ge Directive 98 68 EEC requirements to the standards of EN 60950 Safety of Information Technology Equipment The RoHS compliant logo indicates that this electronic product does not exceed the limit requirements of toxic hazardous substances or elements as set forth in Directive 2002 95 EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazar...

Страница 11: ...llect data from the same network segments at the same time eliminating contention for access to the network Also these ports can be configured as more input ports to include more network segments for monitoring Network administrators no longer need a separate tool for each network segment to achieve simultaneous 24x7 monitoring of multiple links nor do they need to switch to a different segment to...

Страница 12: ... analysis enables you to seamlessly analyze a packet at multiple points in your network with one tool know exactly what is happening to data as it moves through your network View all the data from multiple network segments allows you to monitor and analyze traffic from asymmetric routing paths load balanced applications and redundant environments Any to Any ports allow Gigabit devices to simultane...

Страница 13: ...32º to 104 F 0º to 40 C Storage Temperature 22º to 149 F 30º to 65 C Operating Range Relative Humidity 5 to 90 non condensing Dimensions H x W x D includes RMC 2 rack mount bracket 1 750 x 7 950 x 7 775 inch 4 44 x 20 19 x 19 75 cm Weight 1 5 lbs shipping 6 5 lbs 0 68 kg shipping 2 95 kg Warranty Two 2 years see Warranty section for details 2 5 VS 1200 S Series Model Specific Specifications VS 120...

Страница 14: ......

Страница 15: ...ware 15 2011 Datacom Systems Inc 3 Hardware Front panel images of the VS 1200 S series are provided in this section 3 1 VS 1200 S Series Front Panels VS 1204BT S VS 1208BT S VS 1210BT SFP S VS 1210BT SFP S ...

Страница 16: ...or OUTPUT by Superuser for use as input or output ports See Serial and Management Port Command Line Interface Superuser Commands SET PORT MONITOR SE PO MO section for more information Ports 1 to 8 VS 1210BT SFP S or VS 1208BT S and Ports 1 to 4 VS 1204BT S are RJ45 connectors used for connection to network devices or tools These jacks have integrated LEDs that display line status and line speed of...

Страница 17: ...ed DB9 Female and is cabled to the COM port of any compatible network tool or PC where HyperTerminal software resides It is the only port that can easily connect the Management PC to set the IP address default 192 168 1 1 for the first time 3 3 2 Power Switch SFP series The front panel POWER 1 POWER 2 LEDs are illuminated green respectively when the DC power switch is depressed ON and DC power is ...

Страница 18: ...ower is available at both the two rear DC power sockets or BT series when DC power is available at both the two rear DC power sockets Either POWER 1 or 2 LED not illuminated when powered indicates a defective power source and immediate investigation as to the cause is required to insure redundant power integrity Although only one switching AC adapter power supply is required to power the configura...

Страница 19: ... VS 1200 S series factory default is off for all Any to Any ports 4 1 1 Basic Functionality Window Size Functionality The CLI window is limited to 24 lines per screen and 80 characters per line If more data than can fit is presented a more prompt is shown on the last line Character Handling Printable character ASCII code 32 126 and non printable noted below Non Printable Character Description ente...

Страница 20: ...m or the shortcut form are entered after the prompt default at the cursor No auto fill mode is available After the topic heading a brief overview of the command display function is given followed by an example Example command input 4 1 3 1 HELP HE or When this command is entered a list of commands their shortcut inputs and their descriptions will display For the use and application of each command...

Страница 21: ...uting Summary SHOW PRODUCT SH PR Show Product Name and Serial Number SHOW TIME SH TI Show System Date and Time SHOW USERS SH US Display Users SU SU Enter Superuser Mode SU SET PASSWORD SU SE PA Set Superuser Password 4 1 3 2 POWER STATUS PO ST This command displays power supply status It is entered and displays data as shown POWER STATUS PO ST Example PO ST Power Supply 1 Good Power Supply 2 Good ...

Страница 22: ...egree of control during both the initial setup and all subsequent moves or changes The GROUP NAME followed by the ports included in the group are displayed It is entered and displays data as shown SHOW GROUPS SH GR Example SH GR TAP 9 Port 9 10 Port 10 4 1 3 5 SHOW MANAGEMENT SH MA This command displays Management RJ45 port information as shown SHOW MANAGEMENT SH MA Example SH MA Security Version ...

Страница 23: ...Type Tap 1 2 Group Member TAP Copies to 2 5 6 7 8 9 10 VLAN Tag Stripping OFF 02 Port 2 CFG 1G Full Duplex Current No Link Type Tap 2 1 Group Member TAP Copies to 1 5 6 7 8 9 10 VLAN Tag Stripping OFF Press any key 4 1 3 7 SHOW PORT ROUTING SH PO RO This command displays all port interface routing in a brief matrix summary as shown SHOW PORT ROUTING SH PO RO Example SH PO RO Outputs 01 02 03 04 05...

Страница 24: ... SH US Example SH US Administrator edituser 4 1 4 Superuser Commands Configuration Access The topic headings in the following section show the long form of the Superuser command set with the shortcut input for the command noted in parenthesis After the topic heading a brief overview of the command display function is given followed by an example Example command input All commands are entered after...

Страница 25: ...is command followed by a text string changes the Base Prompt as shown SET PROMPT SE PR prompt text up to 32 characters Example SE PR Datacom Datacom 4 1 4 4 ADD USER AD US This command is used to add users to the configurable product as shown ADD USER AD US Example AD US Enter New Username newuser Confirm Password User newuser has been saved 4 1 4 5 EDIT USER ED US This command edits Usernames Pas...

Страница 26: ...WAY GA This command configures the IP address default 192 168 1 1 Subnet Mask default 255 255 255 0 and Default Gateway default 0 0 0 0 parameters Initially it is highly recommended that this be done through the direct serial connection using the HyperTerminal or equivalent terminal emulation application Only those variables that require configuration need to be entered The parameters may be enter...

Страница 27: ...0 groups is allowed Groups as designated by the administrator Superuser belong to the same logical group Specifically groups can be configured as if they were a single logical port enabling a high degree of control during both the initial setup and all subsequent moves or changes as shown SET PORT GROUP SE PO GR group name OFF or CONTAINS port list Example SE PO GR DatacomPorts CONTAINS 4 5 6 SE P...

Страница 28: ...ULL AUTO This command changes the port speed for a single port or a group of ports as shown SET PORT SPEED Comma separated list of Port numbers port names or group names Speed duplex Example SE PO SP 4 6 7 8 100HALF Speed set for port s 4 6 7 8 4 1 4 14 SET PORT VTAG SE PO VT This command is used to change the capability of a port to either pass VLAN Tags or strip them from a frame and recalculate...

Страница 29: ...E TT This command sets the TELNET service default ENABLED process It is entered as shown SET TELNET SE TT OFF or ON Example 1 SE TT OFF The Telnet protocol will be disabled at end of session Example 2 SE TT ON The Telnet protocol will be enabled at end of session 4 1 4 18 SET SSH SE SH This command sets the SSH service default ENABLED process It is entered as shown SET SSH SE SH OFF or ON Example ...

Страница 30: ...sfully loaded Example 2 SE SH KY DSA Please cut paste the PEM encoded dsa SSH key right mouse click if Putty or Terra Term dsa SSH Key successfully loaded 4 1 4 20 SET PING SE PI This command enables or disables PING default ENABLED service process It is entered as shown SET PING ENABLE SE PI EN OFF or ON Example 1 SE PI EN OFF The PING protocol is now disabled Example 2 SE PI EN ON The PING proto...

Страница 31: ...aracters DES characters12 SNMP V3 user created 4 2 SERIAL Port Configuration DB9 Note Use of the SERIAL DB9 port which is fairly simple and straight forward is strongly recommended for initial configuration of the hardware 4 2 1 HyperTerminal Once series connection is made any freely available terminal emulator may be utilized however Microsoft HyperTerminal is the preferred terminal emulation pro...

Страница 32: ...ttings if an alternate terminal emulator is used IMPORTANT For Host Address if initial IP Address HAS NOT BEEN configured use 192 168 1 1 default or if initial IP Address HAS BEEN configured use the Local Area Network address input during initial IP Address configuration HyperTerminal terminal emulator enter TCP IP Winsock Host Address nnn nnn nnn nnn i e 192 168 1 1 or Local Area Network Port Num...

Страница 33: ... in the IP Address Configuration section 4 4 IP Address Configuration All VS 1200 S series are shipped with a factory default configuration as follows IP Address 192 168 1 1 Subnet Mask 255 255 255 0 Default Gateway 0 0 0 0 IMPORTANT If you expect to remotely connect to the VS 1200 S series you must change the IP Address Subnet Mask and Default Gateway to match your Local Area Network as described...

Страница 34: ...port on your PC and connect the DB9 Male pin to the SERIAL port on the unit NOTE For PCs without 9 pin serial ports check with your product representative for available sources of a USB to RS 232 Plug in Adapter Step 3 Open the HyperTerminal application on your PC by selecting START All Programs Accessories Communications HyperTerminal Step 4 Name a new HyperTerminal connection and select OK ...

Страница 35: ...en click OK Step 7 You are now connected hit the Enter key twice in succession i e Enter Enter to display the Enter Username prompt All Usernames and passwords are case sensitive Type Administrator default value and press the Enter key At the Enter Password prompt type admin default value and press the Enter key to display the command line prompt At the command line prompt type su and press the En...

Страница 36: ...t gateway Press the Enter key to continue Step 11 SHOW SH by typing sh and press the Enter key to display and affirm that the pending IP Address IP Subnet and IP Default Gateway match the intended Local Area Network input IP Address IP Subnet and IP Default Gateway Step 12 If the pending IP Address is not correct repeat Step 8 if the pending IP Subnet is not correct repeat Step 9 and if the pendin...

Страница 37: ...etwork location 4 4 2 IP Address Configuration with TELNET The IP address of the configurable series can be configured via a RJ45 connection with a TELNET application available on most Windows PCs or an open source free software terminal emulator for MS Windows Step 1 Connect the VS 1200 S with one of the supplied switching AC adapters and AC line cords into an external power source Either POWER 1...

Страница 38: ... START Control Panel Network Connections Step 4 Right click the Local Area Connection and from the drop down menu select Properties Highlight Internet Protocol TCP IP and highlight and click the Properties box Check the button Use the following IP Address Use IP Address 192 168 1 5 and Subnet Mask 255 255 255 0 Click OK ...

Страница 39: ...sories Command Prompt Step 6 In the Command Prompt window at the prompt enter TELNET and hit the Enter key To see a list of available Microsoft Telnet Client Commands at the prompt enter and hit the Enter key Supported commands will be displayed Step 7 At the Command Prompt window prompt enter o 192 168 1 1 and hit the Enter key ...

Страница 40: ...ailable commands at either the or command line prompt type and press the Enter key Step 9 SET IP SE IP by typing se ip xxx xxx xxx xxx corresponding to a valid IP address for your network Press the Enter key to continue Step 10 SET SUBNET SE SU by typing se su xxx xxx xxx xxx corresponding to your network s subnet mask Press the Enter key to continue Step 11 SET GATEWAY SE GA if needed by typing s...

Страница 41: ... key to save the network address changes which ends the connection session as indicated in a few seconds by the Windows informational message balloon pop up icon Local Area Connection A network cable is unplugged Step 15 Close TELNET Step 16 Disconnect the DRL512 2M R serial cable Step 17 Install the VS 1200 S series in your chosen network location 4 5 Exercise CLI Setting Ports PREMISE The config...

Страница 42: ...C can handle both sides of the network conversation at once Port 7 and 8 s Network IDS s network interface cards cannot handle the whole conversation at once and must use two separate NICs for each side of the conversation It can be setup either way to fit your network devices tools requirements CONFIGURATION For the connections to be properly set use the syntax below in the Command Line Interface...

Страница 43: ...previous settings present go through Ports 1 10 and set them to OFF as shown SET PORT MONITOR 1 OFF SET PORT MONITOR 2 OFF SET PORT MONITOR 3 OFF SET PORT MONITOR 4 OFF SET PORT MONITOR 5 OFF SET PORT MONITOR 6 OFF SET PORT MONITOR 7 OFF SET PORT MONITOR 8 OFF SET PORT MONITOR 9 OFF SET PORT MONITOR 10 OFF Now you can begin setting the Tap and Monitor ports as to which port inputs the data and whi...

Страница 44: ...output for Port 2 s input output which is set with this syntax SET PORT MONITOR 8 FROM 2 Port 9 is set as output for Ports 1 and 2 s input output which is set with this syntax SET PORT MONITOR 9 FROM 1 2 Port 10 is set as output for Ports 1 2 3 and 4 s input which is set with this syntax SET PORT MONITOR 10 FROM 1 2 3 4 As a quick check show port routing interface matrix with this syntax SH PO RO ...

Страница 45: ... enter o nnn nnn nnn nnn open hostname i e o Local Area Network IP Step 1 Open the Command Prompt on your PC by selecting START All Programs Accessories Command Prompt Step 2 In the Command Prompt window at the prompt enter TELNET and hit the Enter key To see a list of available Microsoft Telnet Client Commands at the prompt enter and hit the Enter key Supported commands will be displayed Step 3 A...

Страница 46: ... Please note that the different versions may use different implementations of the SSH protocol and therefore you may not be able to connect to an SSH1 server using SSH2 client software or vice versa Restrictions for Secure Shell Version 2 Support Execution Shell and remote command execution are the only applications supported Compression is not supported The following instructions illustrate a typ...

Страница 47: ... the first time you will probably see a message looking something like this The warning message above asks you whether you want to trust this host key or not This is a feature of the SSH protocol it is designed to protect against a network attack known as spoofing which redirects your connection to a different computer so that you send your password to the wrong machine To prevent this attack each...

Страница 48: ...pt type and press the Enter key Step 5 Type Exit and press the Enter key to end the connection session Close PuTTy 4 7 SNMP Configuration IMPORTANT SNMP MUST be enabled and there MUST be at least one SNMP user for the SNMP feature to work Once installation of the Link Aggregation Tap has been completed in your chosen network location if at least one SNMP user has not been created refer to the CLI ...

Страница 49: ...es you should observe before you install an SFP module in your VS 1200 S series unit NOTE You can install and remove SFP modules with power on to the system however it is strongly recommended that you do not install or remove the SFP module with fiber or copper cables attached to it Disconnect all cables before removing or installing a SFP module CAUTION Prevent system problems use only Datacom Sy...

Страница 50: ...il completed Step 3 Attach the appropriate network cable to the LC type or RJ45 type connector on the SFP module For fiber optic SFP modules you can use either simplex or duplex connectors For simplex connectors two cables are required one cable for transmit Rx and a second cable for receive Rx For duplex connectors only one cable that has both Tx and Rx connectors is required 4 8 4 Removing the S...

Страница 51: ...iate investigation as to the cause is required to insure redundant power integrity 1 Step 1 Using the supplied Power Adapters and AC Line Cords plug the VS 1200 S series into different circuit external power sources Although only one power supply is required to power the configurable unit use of a second independent power source is strongly recommended to assure uninterrupted monitoring Furthermor...

Страница 52: ... the MANAGEMENT port 100 Mbs Full Duplex connection of the typical VS 1200 S configurable series hardware installation Step 1 Connect a network cable to the MANAGEMENT port RJ45 socket The MANAGEMENT port RJ45 left LED illuminates green when link has been established with the network The MANAGEMENT port right LED illuminates green when passing data The MANAGEMENT PORT is an RJ45 socket used for 10...

Страница 53: ...VS 1200 S Series Functional Drawing 53 2011 Datacom Systems Inc 6 VS 1200 S Series Functional Drawing VS 1210BT SFP S VS 1210SFP S VS 1208BT S VS 1204BT S ...

Страница 54: ...VS 1200 S Data Acccess Switch 54 2011 Datacom Systems Inc ...

Страница 55: ...ccess from the users and server to server traffic GOAL This application will use a VS 1210BT SFP S as follows 1 TAP access to critical server 2 Aggregate SPAN 3 Provide access for analysis security and recording devices The first goal requires an external tap between the server switch and the critical financial server The tap copies all the data going to the financial server and can t be shutdown ...

Страница 56: ...ion open HyperTerminal on your Management PC using the VS 1210BT SFP S SERIAL DB9 port Settings are found in the Initial Configuration SERIAL Port Configuration DB9 HyperTerminal section Press twice Enter key and Enter key Enter Username default Administrator and Enter key Enter Password default admin and Enter key Default prompt is the symbol Enter superuser mode type su and Enter key Enter Passw...

Страница 57: ...rt 8 is set as output for Port 3 s input which is set with this syntax SET PORT MONITOR 8 FROM 3 Port 9 is set as output for Port 3 s input which is set with this syntax SET PORT MONITOR 9 FROM 3 Port 10 is set as output for Ports 1 2 and 3 s input which is set with this syntax SET PORT MONITOR 10 FROM 1 2 3 CONCLUSION The VS 1210BT SFP S provides the ability to aggregate data streams from TAPs an...

Страница 58: ...r bound access from the users and view server to server traffic GOAL This application will use a VS 1210SFP S as follows 1 Fiber TAP access to optical networks 2 Aggregate traffic to provide access for analysis security and recording devices The first goal requires an external fiber taps between the optical network devices The tap makes a copy of all the data going to the financial server and can ...

Страница 59: ...user prompts For Configuration open TELNET on your Management PC and open a hostname connection with the VS 1210SFP S MANAGEMENT RJ45 port Settings are found in the Initial Configuration MANAGEMENT Port Configuration RJ45 TELNET section Enter Username default Administrator and Enter key Enter Password default admin and Enter key Default prompt is the symbol Enter superuser mode type su and Enter k...

Страница 60: ...Port 7 is set as output for Port 2 and 4 s input which is set with this syntax SET PORT MONITOR 7 FROM 2 4 Port 8 is set as output for Port 2 and 4 s input which is set with this syntax SET PORT MONITOR 8 FROM 2 4 Port 9 is set as output for Port 1 2 3 and 4 s input which is set with this syntax SET PORT MONITOR 9 FROM 1 2 3 4 Port 10 is set as output for Ports 4 s input which is set with this syn...

Страница 61: ...turn it to you freight collect DSI shall have no responsibility for any deficiency resulting from accidents misuse modifications power disturbances including use of a power supply not specified by DSI or various other forms of disaster e g earthquakes floods etc PLEASE DO NOT ATTEMPT TO RETURN ANY ITEM PRIOR TO RECEIVING A RETURN MATERIAL AUTHORIZATION RMA NUMBER FROM DATACOM CUSTOMER SERVICE AT 3...

Страница 62: ......

Страница 63: ... support datacom com Copyright Notice Copyright C 2010 Datacom Systems Inc All Rights Reserved use is subject to license terms Abstract This memo defines a set of agent identities used to identify Datacom SNMP agents and a set of agent capabilities used to convey the capabilities of Datacom SNMP Agents Table of Contents 1 Introduction 2 The Internet Standard SNMP Management Framework 3 Conventions...

Страница 64: ...ormation SMI This memo specifies a MIB module that is compliant to the SMIv2 which is described in STD 58 RFC 2578 RFC2578 STD 58 RFC 2579 RFC2579 and STD 58 RFC 2580 RFC2580 3 Conventions The key words MUST MUST NOT REQUIRED SHALL SHALL NOT SHOULD SHOULD NOT RECOMMENDED MAY and OPTIONAL in this document are to be interpreted as described in RFC2119 4 Overview of the Datacom Agent Capabilities MIB...

Страница 65: ...ies are defined within the Datacom agentCaps subtree Refer to section 6 Mapping of the AGENT CAPABILITIES macro in RFC 2580 Conformance Statements for SMIv2 RFC2580 for further information on the use of agent capabilities statements by management application and SNMP agents An example of values exposed in the sysORTable follows sysORID 1 dcomCapsSNMPv3Base sysORDescr 1 supports SNMPv3 sysORUpTime ...

Страница 66: ...ties for Datacom SNMP Agents Copyright C 2010 Datacom Systems Inc All rights reserved Use is subject to license terms This version of the DATACOM AGENT CAPS MIB module is part of Datacom publication The Datacom Agent Capabilities MIB July 2010 See the publication itself for full legal notices Revision log REVISION 201007260000Z 26 July 2010 midnight DESCRIPTION Initial version as part of Datacom p...

Страница 67: ...y the sysObjectID object agentIdents 227 Agent Capabilities dcomCapsSNMPv3Base AGENT CAPABILITIES PRODUCT RELEASE Various releases Indicates support for the base set of SNMPv3 MIB modules STATUS current DESCRIPTION The Agent Capabilities statement indicating support for the base set of SNMPv3 MIB modules SUPPORTS SNMP MPD MIB INCLUDES snmpMPDGroup SUPPORTS SNMP FRAMEWORK MIB INCLUDES snmpEngineGro...

Страница 68: ...asicGroup SUPPORTS SNMPv2 MIB INCLUDES snmpGroup snmpSetGroup systemGroup snmpBasicNotificationsGroup agentCaps 1 dcomCapsAres1dot0dot0 AGENT CAPABILITIES PRODUCT RELEASE Datacom ARES version 1 0 0 STATUS current DESCRIPTION The Agent Capabilities statement for Datacom ARES version 1 0 0 SUPPORTS IF MIB INCLUDES ifGeneralInformationGroup linkUpDownNotificationsGroup VARIATION ifPhysAddress ACCESS ...

Страница 69: ...y the following states are implemented up 1 down 2 unknown 4 VARIATION ifAlias ACCESS not implemented DESCRIPTION not implemented SUPPORTS DATACOM POWER SUPPLY MIB INCLUDES dcomPowerSupplyStatusGroup dcomPowerSupplyEventGroup agentCaps 2 END 6 Acknowledgments The production and maintenance of this memo is a group effort of the Datacom development team 7 Security Considerations This module does not...

Страница 70: ...TD 58 RFC 2578 April 1999 RFC2579 McCloghrie K Perkins D Schoenwaelder J Case J Rose M and S Waldbusser Textual Conventions for SMIv2 STD 58 RFC 2579 April 1999 RFC2580 McCloghrie K Perkins D Schoenwaelder J Case J Rose M and S Waldbusser Conformance Statements for SMIv2 STD 58 RFC 2580 April 1999 8 2 Informative References RFC3410 Case J Mundy R Partain D and B Stewart Introduction and Applicabil...

Страница 71: ...rticular it defines managed objects and notifications exposing status information about power supplies associated with Datacom products Section Contents 1 Introduction 2 The Internet Standard SNMP Management Framework 3 Conventions 4 Overview 4 1 Use of SMIv2 Syntax and Textual Conventions 4 1 1 SMIv2 Syntax 4 1 1 1 Unsigned32 4 1 1 2 INTEGER 4 2 SNMPv2 TC Textual Conventions 4 2 1 TimeStamp 4 3 R...

Страница 72: ...3 Conventions The key words MUST MUST NOT REQUIRED SHALL SHALL NOT SHOULD SHOULD NOT RECOMMENDED MAY and OPTIONAL in this document are to be interpreted as described in RFC2119 4 Overview This section provides an overview of this MIB module Section 4 1 provides a discussion on the use of SMIv2 Syntax and Textual Conventions Section 4 2 discusses the relationship of this MIB module to other MIB mod...

Страница 73: ...tate of a power supply The named number enumerated values are as follow stateUnknown 1 the current state is unknown stateDown 2 the current state is down stateUp 3 the current state is up 4 2 SNMPv2 TC Textual Conventions This section discusses Textual Conventions defined in the SNMPv2 TC RFC2579 and used in this MIB module 4 2 1 TimeStamp There is one object defined in this MIB module using the S...

Страница 74: ... the complete inventory of components associated with a managed system Thus this MIB module is used to expose management information relevant to power supplies associated with Datacom products Note that the use of this MIB module does not preclude the potential for future use of the ENTITY MIB and ENTITY STATE MIB for Datacom products 4 4 Organization of This MIB Module This MIB module organizes i...

Страница 75: ...that a power supply has transitioned into the down state The power supply involved in this event is identified by the dcomPowerSupplyIndex value appended to the object name of the dcomPowerSupplyStatus variable binding 4 5 Notes for Management Applications when the SNMP agent re initializes subsequent to receiving the coldStart event notification a management application will receive a dcomPowerSu...

Страница 76: ...3 1585 EMail support datacomsystems com URL http www datacomsystems com Send comments to support datacomsystems com DESCRIPTION This MIB modules defines managed objects and notifications exposing status information about power supplies associated with Datacom products Copyright C 2010 Datacom Systems Inc All rights reserved Use is subject to license terms This version of the DATACOM POWER SUPPLY M...

Страница 77: ...TIFICATION TYPE definitions for asynchronous reporting of events about power supplies associated with Datacom products datacomPowerSupplyMib 2 dcomPowerSupplyConformance OBJECT IDENTITY STATUS current DESCRIPTION This subtree contains conformance statements for this MIB module datacomPowerSupplyMib 3 assignments under dcomPowerSupplyEvents dcomPowerSupplyEventsNotify OBJECT IDENTITY STATUS current...

Страница 78: ...SEQUENCE OF DcomPowerSupplyStatusEntry MAX ACCESS not accessible STATUS current DESCRIPTION A table of status information for power supplies associated with a Datacom product dcomPowerSupplyObjects 1 dcomPowerSupplyStatusEntry OBJECT TYPE SYNTAX DcomPowerSupplyStatusEntry MAX ACCESS not accessible STATUS current DESCRIPTION Status information for a power supply associated with a Datacom product IN...

Страница 79: ...mber enumerated values are as follow stateUnknown 1 the current state is unknown stateDown 2 the current state is down stateUp 3 the current state is up dcomPowerSupplyStatusEntry 2 dcomPowerSupplyLastChange OBJECT TYPE SYNTAX TimeStamp MAX ACCESS read only STATUS current DESCRIPTION The value of sysUptime when this power supply transitioned into its current state A value of zero 0 indicates this ...

Страница 80: ...JECTS dcomPowerSupplyStatus STATUS current DESCRIPTION A dcomPowerSupplyEventDown event notification provides an indication that a power supply has transitioned into the down state The power supply involved in this event is identified by the dcomPowerSupplyIndex value appended to the object name of the dcomPowerSupplyStatus variable binding dcomPowerSupplyEventsNotify 2 conformance and compliance ...

Страница 81: ...ociated with Datacom products dcomPowerSupplyGroups 2 END 6 Acknowledgments The production and maintenance of this memo is a group effort of the Datacom development team 7 Security Considerations There are no management objects defined in this MIB module that have a MAX ACCESS clause of read write and or read create So if this MIB module is implemented correctly then there is no risk that an intru...

Страница 82: ... users that have legitimate rights to indeed GET or SET change create delete them 8 References 8 1 Normative References RFC2119 Bradner S Key words for use in RFCs to Indicate Requirement Levels BCP 14 RFC 2119 March 1997 RFC2578 McCloghrie K Perkins D Schoenwaelder J Case J Rose M and S Waldbusser Structure of Management Information Version 2 SMIv2 STD 58 RFC 2578 April 1999 RFC2579 McCloghrie K ...

Страница 83: ...pport datacom com Copyright Notice Copyright C 2010 Datacom Systems Inc All Rights Reserved use is subject to license terms Abstract This memo defines a portion of the Management Information Base MIB for use with network management protocols in The Internet community In particular it defines the top level structure of management information and administrative registrations within the Datacom priva...

Страница 84: ...ecifies a MIB module that is compliant to the SMIv2 which is described in STD 58 RFC 2578 RFC2578 STD 58 RFC 2579 RFC2579 and STD 58 RFC 2580 RFC2580 3 Conventions The key words MUST MUST NOT REQUIRED SHALL SHALL NOT SHOULD SHOULD NOT RECOMMENDED MAY and OPTIONAL in this document are to be interpreted as described in RFC2119 4 The Datacom Structure of Management Information Datacom enterprise MIB ...

Страница 85: ...N TYPE MODULE COMPLIANCE OBJECT GROUP and NOTIFICATION GROUP definitions occur within the respective Datacom MIB module Additions and deprecations to assignments within the top level of the Datacom private enterprise name space may occur from time to time as documented in revisions to this memo 5 Definitions DATACOM SMI MIB DEFINITIONS BEGIN IMPORTS MODULE IDENTITY OBJECT IDENTITY enterprises FROM...

Страница 86: ...VISION 201007010000Z 1 July 2010 midnight DESCRIPTION Initial version as part of Datacom publication The Datacom SMI MIB July 2010 datacomMibs 1 datacom OBJECT IDENTITY STATUS current DESCRIPTION The private enterprise number assigned to Datacom by the Internet Assigned Numbers Authority IANA enterprises 9762 agentIdents OBJECT IDENTITY STATUS current DESCRIPTION The agentIdents subtree provides a...

Страница 87: ...ODULE COMPLIANCE OBJECT GROUP and NOTIFICATION GROUP definitions occur within the respective Datacom MIB module datacom 3 The following list tracks assignments known as of this revision of the DATACOM SMI MIB datacomSmiMib datacomMibs 1 reserved datacomMibs 2 datacomAgentCapsMib datacomMibs 3 datacomPowerSupplyMib datacomMibs 4 END 6 Acknowledgments The production and maintenance of this memo is a...

Страница 88: ...t Information Version 2 SMIv2 STD 58 RFC 2578 April 1999 RFC2579 McCloghrie K Perkins D Schoenwaelder J Case J Rose M and S Waldbusser Textual Conventions for SMIv2 STD 58 RFC 2579 April 1999 RFC2580 McCloghrie K Perkins D Schoenwaelder J Case J Rose M and S Waldbusser Conformance Statements for SMIv2 STD 58 RFC 2580 April 1999 8 2 Informative References RFC3410 Case J Mundy R Partain D and B Stew...

Страница 89: ...ct the Product Selection from the drop down list browse to find the binary file i e C Program Files DSI input the IP address of the product and click the Program box to begin 3 Provide Login information Username Administrator default Password admin default click the Login box to continue 4 Programming Status window opens to display the programming operation Erasing the micro should begin within 30...

Страница 90: ...Datacom Systems Inc 9 Adler Drive East Syracuse NY 13057 TEL 315 463 9541 FAX 315 463 9557 http www datacomsystems com Datacom Systems Inc Access Your Network TM ...

Отзывы: