Initial Configuration
33
© 2011 Datacom Systems Inc
4.3.2
TELNET
Most network equipment and operating systems with a TCP/IP stack also support some kind of
TELNET service server for remote configuration. Security-related shortcomings have limited
TELNET (TErminaL NETwork) usage, although TELNET is still widely used when diagnosing
problems, manually "talking" to other services without specialized client software, and administration
of network elements such as integration and maintenance of core network elements.
IMPORTANT
: For
hostname,
if initial IP Address
HAS NOT BEEN
configured, use
192.168.1.1
(default) or if initial IP Address
HAS BEEN
configured, use the
Local Area Network
address setting
input during initial IP Address configuration.
TELNET
using
MANAGEMENT
RJ45 - software configuration of the hardware
At the Windows command prompt enter:
telnet
At the Microsoft Telnet> prompt enter:
o nnn.nnn.nnn.nnn (open hostname)
[i.e., o 192.168.1.1
or
Local Area Network])
After reviewing the
Command Line Interface (CLI)
section and
Exercise - CLI setting Ports
section, detailed IP Address configuration can be found in the
IP Address Configuration
section.
4.4
IP Address Configuration
All VS-1200-S series are shipped with a
factory default
configuration as follows:
IP Address:192.168.1.1; Subnet Mask: 255.255.255.0; Default Gateway: 0.0.0.0
IMPORTANT:
If you expect to remotely connect to the VS-1200-S series, you must change the IP
Address, Subnet Mask and Default Gateway to match your Local Area Network as described in
either the
'IP Address Configuration with HyperTerminal
' section or '
IP Address Configuration
with TELNET
' section.
Note:
If your VS-1200-S already has the IP Address, Subnet Mask and Default Gateway set for
your network, you may proceed to the '
Small Form-Factor Plug Module
' section.
4.4.1
IP Address Configuration with HyperTerminal
The IP address of the configurable series can be configured via a serial connection with either
Microsoft's
HyperTerminal
application (available on most Windows PCs) or an open source free
software terminal emulator for MS-Windows.
Step 1.
Plug the VS-1200-S into an external power source using a supplied switching AC adapter
and AC line cord. Note,
POWER 1
or
2
LED is illuminated
green
indicating power is available from
the connected DC power socket. The other
POWER
LED is not illuminated, indicating a lack of
power to the unconnected DC power socket.
19
41
33
33
37
49