Datacom Systems Inc. 2016
52
DURAstream
™
DS-1404, DS-1406, DS-2408 FASTstart Guide
Example Configuration Commands
Management Port Setup
Command
Explanation
Management Set IP 192.168.1.2
If you plan to access the Durastream™ over a network,
you should first set up the IP information to connect to it
remotely. The configuration should match your
network’s topology.
Management Set Subnet 255.255.255.0
Management Set Gateway 192.168.1.1
Network Port Setup
Command
Explanation
Port 3 Set Speed 1G-Auto
Since the network link that the Durastream™ is
being installed on is 1G fiber, the ports must be
configured to 1G speed. They are fiber by default.
Port 4 Set Speed 1G-Auto
Appliance Port Setup
Command
Explanation
Port 3 Set Media Copper
Since a copper monitoring tool is being used,
the appliance ports (3 and 4) must be set to
copper media type and 1G speed.
Port 3 Set Speed Auto
Port 4 Set Media Copper
Port 4 Set Speed Auto
*Optional* Heartbeat Modification
Command
Explanation
Bypass Set Freq 100
Heartbeats are sent every 100ms.
Bypass Set Expire 100
DURAstream™ waits 100 ms before considering
a heartbeat to be missing.
Bypass Set Fail 3
If the DURAstream™ misses 3 consecutive
heartbeats it will bypass the appliance.
Bypass Set Reactivate 2
If the DURAstream™ receives 2 consecutive
heartbeats it will put the appliance inline.
Bypass Set Direction Uni
The DURAstream™ will send heartbeats on the
first appliance port, to be received by the second.
Bypass Set Packet Eth
The DURAstream™ will send Ethernet heartbeats
through the appliance.
Содержание DS-1404
Страница 1: ...DS 1404 DS 1406 DS 2408 Bypass Switches FASTstart Guide April 2016 2016 Datacom Systems Inc ...
Страница 29: ...Datacom Systems Inc 2016 29 DURAstream DS 1404 DS 1406 DS 2408 FASTstart Guide ...
Страница 30: ...Datacom Systems Inc 2016 30 DURAstream DS 1404 DS 1406 DS 2408 FASTstart Guide ...
Страница 31: ...Datacom Systems Inc 2016 31 DURAstream DS 1404 DS 1406 DS 2408 FASTstart Guide ...