DATA DOMAIN DD690g INSTALLATION AND SETUP GUIDE | SIDE 1

AbOuT EXTErNAl STOrAGE cONTrOllErS AND POrTS

The storage array can have single or multiple controllers. Each controller 
can have multiple ports.

One storage controller port is required for each direct-attached connection 
to the gateway system.

A SAN-attached storage controller port used for gateway connectivity 
cannot be shared by other SAN-attached hosts that access the storage array.

Optional redundant connectivity is supported. If you do not use redundant    
connectivity, use the external array management interface to disable port 
and controller failover.

AbOuT EXTErNAl ArrAY STOrAGE

External storage disks should be dedicated to the gateway and not shared 
with other hosts.

Disks should be configured into one or more LUNs and exported to the 
gateway.

A LUN should be configured using as many disks as possible.  

All disks in the LUNs must be identical drives and have identical RAID 
configurations.

The gateway can work with different RAID configurations, but the RAID 
configurations that provide the fastest possible 256 KB sequential read 
access should be used.

A volume on the gateway system must have the same types of LUN but 
the size can vary.

The minimum data size for each LUN that a gateway system can access is 
400 GiB for initial install. For subsequent LUNs after the initial install, 100 
GiB is the minimum.

AbOuT GATEWAY luN cONFIGurATION rulES

A gateway system supports one volume composed of one to 16 LUNs. 
LUN numbers must start at 0 (zero) but need not be contiguous.

The maximum LUN number accepted by our gateway systems is 255.

To use the maximum amount of space on a system, create multiple LUNs 
and adjust the LUN data sizes to comply with the defined rules. The “data 
size” means the size of the LUN presented to the Data Domain gateway 
system by the third-party external storage.

cONNEcT EXTErNAl STOrAGE

The Data Domain gateway system can be direct-attached to the External 
Storage Array as in Figure 4, or Fibre Channel (FC) SAN-attached as in Figure 
5. A DD690g gateway system has two dual-port FC Host Bus Adapters 
(HBAs). The first HBA card port is located in PCI-e slot 2 and the second in 
PCI-e slot 1 on the rear panel. See Figure 2.
Depending on your choice of connectivity, follow the appropriate connectivity 
defined in the corresponding figures. For all connectivity, use a fiber optical 
cable of appropriate length with an LC connector to connect to one of the FC 
HBA card ports on the back of the Data Domain system (see 

1

 in Figure 4 or 

Figure 5). Connect the other end as noted in Figure 4 or Figure 5 (see 

2

 in 

the figures). If the system is SAN-attached, install the additional optical cables 
from the FC switch to the appropriate ports on the external storage.
For availability of multi-path failover functionality, consult with the 

Data 

Domain Gateway Compatibility Matrix

 on the Data Domain Support web site.

FIGurE 4: DIrEcT-ATTAcHED cONFIGurATION 

FIGurE 5: SAN-ATTAcHED cONFIGurATION 

crEATE luNS 

On the external storage array, create the LUNs for use by the Data Domain 
gateway system. Instructions for creating LUNs are specific to your third-
party storage. See the 

Installation Guide

 on the Data Domain Support 

web site under Integration Documentation.

On the external storage array, configure LUN masking so that the Data 
Domain gateway system can see only those LUNs that should be available 
to the Data Domain gateway system.

FIbrE cHANNEl ZONING cONFIGurATION

When attached to a Fibre Channel SAN, every zone for the DD690g gateway 
system and external storage arrays must be created in the SAN.
Consult information in the SANs Integration Documentation and 
Compatibility Matrices on the Data Domain Support web site. For array 
specific zoning configuration details, consult the appropriate third-party array 
vendor documentation.

External Storage configuration

Содержание DD690g

Страница 1: ...Turn the system on Note Third party SAN storage attached to the DD690g must be zoned before you power on the Data Domain system Attach the bezel 10 Collect the information needed for installation Enter the information in section 2 Define the Data Domain System Information for Your Site found to the far right Install Hardware 1 The steps for a complete installation and configuration are 1 Install H...

Страница 2: ...Operator Panel LEDs LED Status Power Active Steady Green Good Unit Fault Steady Amber Fault Enclosure ID Blue Only when activated 3 9 4 10 7 11 8 12 1 1 1 2 1 2 5 1 3 6 1 4 Front Operator Panel Buttons Push Button Definition Power Press to start boot if system is not running Never shut down the system by pressing the power button System Reset Resets hardware and firmware Use ballpoint pen to activ...

Страница 3: ...way system by the third party external storage connect external storage The Data Domain gateway system can be direct attached to the External Storage Array as in Figure 4 or Fibre Channel FC SAN attached as in Figure 5 A DD690g gateway system has two dual port FC Host Bus Adapters HBAs The first HBA card port is located in PCI e slot 2 and the second in PCI e slot 1 on the rear panel See Figure 2 ...

Страница 4: ...el Delete all new values and go to the next section 4 Retry Restart the input entry at the beginning of the current section The value entered previously appears as the default value at each prompt CONFIGURE THE LUNS 4 Use the disk show hardware command to find out the size of each LUN 4 Use the disk show raid info command to check which LUNs are available 4 Use disk add dev to put a LUN into use b...

Страница 5: ...pecific Data Domain Integration Documentation at https my datadomain com US en integration jsp CIFS The CIFS configuration section in the Perform Initial System Configuration section sets up the CIFS clients to allow access to backup on the Data Domain system You need to set up the CIFS clients as well to allow access to backup on the Data Domain system For additional configuration informa tion se...

Страница 6: ...ensure adequate airflow for cooling Front Bezel Clearance 1 56 inches 4 0 cm of unobstructed clearance Back Panel Clearance 5 inches 12 7 cm of unobstructed clearance Power Grounding Two AC power outlets with an earth ground conductor safety ground A safe electrical earth connection must be provided to each power cord Voltage 100 120 V or 200 240 V Frequency 50 to 60 Hz Site Requirements For infor...

Отзывы: