background image

Copyright © 2009 Data Domain, Inc. All rights reserved.

Data Domain, Inc. believes information in this publication is accurate as of its publication date. This publication could include technical inaccuracies or typographical errors. The information is subject to change without notice. Changes are periodically added to the information herein; 
these changes will be incorporated in new additions of the publication. Data Domain, Inc. may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time. Reproduction of this publication without prior written permission is forbidden.

The information in this publication is provided “as is.” Data Domain, Inc. makes no representations or warranties of any kind, with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose.

Data Domain and Global Compression are trademarks of Data Domain, Inc. All other brands, products, service names, trademarks, or registered service marks are used to identify the products or services of their respective owners. 761-0011-0002 Revision A

Requirement

Description and Specification

Vertical Space in Standard 
19”, Four Post Rack

2U. Do not use a two-post rack. See the included slide rail and installation documentation instructions for installing in a rack.

Air Conditioning

Use air conditioning that can cope with the maximum BTU/hr thermal rating.

Temperature Controls

Use adequate temperature control with a gradient (change) not to exceed 30° C in an hour.

Ventilation and Airflow

In a closed or multi-unit rack, ensure that the unit has adequate airflow through the front bezel and back panel and that the 
ambient air temperature requirements are met. Ensure that the front bezel and back panel clearances are met. If installing in 
a closed cabinet, ensure that the front and rear doors have at least 85% open area to ensure adequate airflow for cooling.

Front Bezel Clearance

1.56 inches (4.0 cm) of unobstructed clearance.

Back Panel Clearance

5 inches (12.7 cm) of unobstructed clearance.

Power / Grounding

Two AC power outlets with an earth ground conductor (safety ground). A safe electrical earth connection must be provided 
to each power cord. 

Voltage:

 100-120 V~ or 200-240 V~. 

Frequency: 

50 to 60 Hz.

Site requirements

For information about:

Go to 

https://my.datadomain.com/US/en/documentation.jsp

 for:

How to configure the system

DD OS Product Documentation for your platform. For DD OS 4.7, see the

 Initial 

Configuration Guide. 

For earlier DD OS versions, see the

 User Guide. 

New features, enhancements, known issues, and late-breaking news 
about your Data Domain software release

The 

Release Notes

 for your software release

How to manage the Data Domain operating system

The

 Data Domain Operating System Administration Guide

 for your software release

How to install and use the OpenStorage (OST) software and plug-in

Data Domain OpenStorage (OST) Administration Guide.  

See the OpenStorage Product Documentation for your platform.

How to replace Data Domain hardware components

Part Installation Guides

How to use third-party applications

Integration Documentation and Compatibility Matrices

Certified storage arrays, storage firmware, and SAN topology

Gateway Compatibility Matrix

 on the Data Domain Support web site

Where to Go for More Information

TEcHNIcAl cONTAcTS

To resolve issues with Data Domain products, contact your contracted support 
provider or visit us online at 

https://my.datadomain.com

.

cOrPOrATE cONTAcTS

2421 Mission College Blvd. 
Santa Clara, CA 95054
866.WE.DDUPE (866.933.3873) or 408.980.4800
[email protected]

contact Information

System Heat Output

Power (VA)

Weight

Rack Mounted Dimensions

Model

Watts

BTU/hr

100-120 / 200-240 V~

 lb / kg

WxDxH in (cm)

DD690g

559

1925

564

51 / 23

19 (48.3)

29.5 (74.9)

3.5 (8.9)

Operating Temperature

41° to 95° F (5° to 35° C)

Operating Humidity

20% to 80%, non-condensing

Non-operating Temperature

-40° to +149° F (-40° to +65° C)

Operating Acoustic Noise

Max 75 dBA, at rear of unit when all drives seek simultaneously

Specifications

Содержание DD690g

Страница 1: ...Turn the system on Note Third party SAN storage attached to the DD690g must be zoned before you power on the Data Domain system Attach the bezel 10 Collect the information needed for installation Enter the information in section 2 Define the Data Domain System Information for Your Site found to the far right Install Hardware 1 The steps for a complete installation and configuration are 1 Install H...

Страница 2: ...Operator Panel LEDs LED Status Power Active Steady Green Good Unit Fault Steady Amber Fault Enclosure ID Blue Only when activated 3 9 4 10 7 11 8 12 1 1 1 2 1 2 5 1 3 6 1 4 Front Operator Panel Buttons Push Button Definition Power Press to start boot if system is not running Never shut down the system by pressing the power button System Reset Resets hardware and firmware Use ballpoint pen to activ...

Страница 3: ...way system by the third party external storage connect external storage The Data Domain gateway system can be direct attached to the External Storage Array as in Figure 4 or Fibre Channel FC SAN attached as in Figure 5 A DD690g gateway system has two dual port FC Host Bus Adapters HBAs The first HBA card port is located in PCI e slot 2 and the second in PCI e slot 1 on the rear panel See Figure 2 ...

Страница 4: ...el Delete all new values and go to the next section 4 Retry Restart the input entry at the beginning of the current section The value entered previously appears as the default value at each prompt CONFIGURE THE LUNS 4 Use the disk show hardware command to find out the size of each LUN 4 Use the disk show raid info command to check which LUNs are available 4 Use disk add dev to put a LUN into use b...

Страница 5: ...pecific Data Domain Integration Documentation at https my datadomain com US en integration jsp CIFS The CIFS configuration section in the Perform Initial System Configuration section sets up the CIFS clients to allow access to backup on the Data Domain system You need to set up the CIFS clients as well to allow access to backup on the Data Domain system For additional configuration informa tion se...

Страница 6: ...ensure adequate airflow for cooling Front Bezel Clearance 1 56 inches 4 0 cm of unobstructed clearance Back Panel Clearance 5 inches 12 7 cm of unobstructed clearance Power Grounding Two AC power outlets with an earth ground conductor safety ground A safe electrical earth connection must be provided to each power cord Voltage 100 120 V or 200 240 V Frequency 50 to 60 Hz Site Requirements For infor...