28
③
Pass the communication power wire (3~6.5mm) through the cable gland and connect the
communication line [+] to BUS+ of RS485 connector, the communication line [-] to BUS-,
respectively.
④
In case of parallel connection, implement parallel connection for 485communication by using
485 IN, OUT.
⑤
Please turn ON the switch (in the above pic.) only in the inverter at the far end of RS485
communication when parallel operation of the inverter and monitoring on the inverter are
connected.
⑥
System ID Number should be set according to the below method during the communication
use. When ID is not assigned, the value is set to 0 by default.
(Menu button – ETC Set – System ID Number – assigning the preferred ID Number to be used)
⑦
Once the communication setup is complete, fasten the plug of the communication gland.