7
SARA manual / SARA - SUB
Fig.5
As shown in the figure, the splay angles
between two adjacent SARA units can
range from0 to 10 degrees maximum
(the numbers on the rear plates of the
SARA units indicate the splay angles in
degrees). When shipped from the facto
-
ry, the units have a security pin stowed
in the “PIN HOLDER” position, inserted
on the right side of their rear plate, and
another pin stowed in the “STORE LINK”
position, inserted on the left. Insert the
first pin in the desired splay angle and in
-
sert the other pin to lock the connecting
rodin thechosenangleplus1.Thatis,if the
desired angle is 4 degrees, insert the “PIN
HOLDER” pin in hole “4” and the “STORE
LINK” pin in hole “5”. When the de-
sired angle is 10 degrees, insert the “PIN
HOLDER” pin in hole “10”, and the “STORE
LINK” pin in the hole marked “10+1”. Make
sure the connecting rod from the unit
on top is fitted between the rear plates
of the unit below to ensure the two units
are securely attached.
4.- Assembly of GS-PL-SARA. Angle settings.
Stability, max and min angle and max
number of units