background image

1

3

3

4

4

7

7

6

6

5

5

1

2

2

D-10

D-20

7

FRONT PANEL

3

4

5

7

6

8

9

2

1

D-100

1: Power Switch: This single pole switch turns the amplifier fully off (but does NOT isolate it from the mains 

supply).

2: Power LED: This indicates when the amplifier is active.  This does NOT indicate the presence of a mains 

supply when the power switch is OFF.

3: Attenuation Controls: These are analogue controls allowing precise level settings. Note that in bridged 

(mono) mode some controls may be inactive.

4: A/P (Auto Protect) LED: If a condition exists, either internally or externally, that could cause damage to either 

the amplifier or the speakers, the protection circuit will disengage the outputs and the A/P LED will illuminate. 

The amplifier will continue to be monitored and depending on the type of fault, will either reset after the fault 

has cleared or require manual resetting by switching off at the mains switch and then on again after a few 

seconds. If the outputs are shorted or if DC is present, the protection circuit will disengage the outputs and the 

A/P LED will illuminate. Temperature related faults will reset if the unit has cooled sufficiently. Output short 

circuits will require manual reset after clearing the fault.

5: Bridge LED: This illuminates when a channel pair have been switched into bridged (mono) mode (channel A

+B or C+D). Note that the partner channel’s LEDs and controls are disabled when a pair of channels are 

bridged.  Bridge switches are on the rear panel.

6: The D-10 and D-20 have Signal LEDs that are active from a minimum output level of approximately 10 Watts 

and are an indication only of signal presence. The D-100 has Signal Meter and OCM indicators: LED bar graphs 

show instantaneous level on each channel to indicate proximity to the limiter threshold. Note that if the PRC 

system is in operation on any channel, this will affect the readout shown on the respective meter. The red LED 

in the meter will illuminate when the limiter threshold has been reached and limiting is occurring. The output 

current monitor (OCM) may activate to limit the output current of the amplifier channel - this can occur even if 

the amplifier has not reached clipping point. The OCM indicator can operate independently of the bar graph 

meter. Typical conditions that may trigger the OCM circuitry would be very low load impedance, or high 

subsonic or VHF levels.

7: Limit LEDs: The amplifiers incorporate signal limiters, which are preset to prevent clipping with high levels of 

drive. The amber LEDs on the front panel illuminate to indicate operation of the limiters.

8: Link LED: This indicates if the channel is linked to its immediate neighbour. If this is illuminated, the 

attenuation control of the channel to the immediate right will not function as both channels are being fed 

from the left hand channel. The link switches are on the rear panel.

9: PRC LED: This illuminates if the Power Reduction Control has been enabled on the respective channel. PRC 

switches are on the rear panel.

E11EVEN SOUND \ 

D series amplifiers 

User’s Manual

Содержание E11EVEN SOUND D Series

Страница 1: ...User s Manual D Series Amplifiers Before operating the device please read the Safety precautions section of this manual www 11sound com Deliver the Nightclub Sound Experience we all Deserve ...

Страница 2: ...ATION OF CONFORMITY WARRANTY INTRODUCTION UNPACKING THE UNIT INSTALLATION FRONT PANEL REAR PANEL CONNECTIONS SPECIFICATIONS APPENDIX I APPENDIX II APPENDIX III E11EVEN SOUND D series amplifiers User s Manual 3 4 5 6 7 8 11 12 13 9 11 14 ...

Страница 3: ...ch as radiators heat registers stoves or other apparatus that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult a...

Страница 4: ...4 DECLARATION OF CONFORMITY D10 D20 D100 E11EVEN SOUND D series amplifiers User s Manual ...

Страница 5: ...f the product All warranty repairs must be exclusively undertaken by the factory or any of its authorised service centers To claim a warranty repair do not open or intend to repair the product All the details related to the warranty such as extended warranties can be found in the SUPPORT section on our website www 11sound com E11EVEN SOUND D series amplifiers User s Manual ...

Страница 6: ... correct type and rating has been fitted Make sure power outlets conform to the power requirements listed on the back of the unit Damage caused by connecting to incorrect AC voltage is not covered by the warranty Mechanical Considerations To ensure that this equipment performs to specification it should be mounted in a suitable rack or enclosure When mounting the unit in a rack or enclosure ensure...

Страница 7: ...ls are bridged Bridge switches are on the rear panel 6 The D 10 and D 20 have Signal LEDs that are active from a minimum output level of approximately 10 Watts and are an indication only of signal presence The D 100 has Signal Meter and OCM indicators LED bar graphs show instantaneous level on each channel to indicate proximity to the limiter threshold Note that if the PRC system is in operation o...

Страница 8: ...facilitate easier wiring in bridged mode Channel B is wired pins 2 hot 2 cold Similarly channel C s output Speakon socket carries Channel D s output Check the table on the rear panel for details 3 D 10 D 20 Bridged Mono switch Depress this switch to run the amplifier in bridged mode Note that the output must be taken from channel A s output Speakon connector on pins 2 hot 1 cold D 100 Bridged mono...

Страница 9: ...ole NL2FC or 4 pole NL4FC connectors can be used Terminations are as follows HOT Pin 1 COLD Pin 1 Additionally Channel A Speakon connector carries Channel B output on Pins 2 2 to allow easy bi amping or bridged operation HOT Pin 2 COLD Pin 2 NOTE 1 Although the cold output terminals are nominally at 0V they should not be joined together otherwi se cross talk may be introduced 2 Because the current...

Страница 10: ...tputs to any other voltage source such as a battery mains source or power supply regardless of whether the amplifier is turned on or off Do not run the output of any amplifier channel back into another channel s input and do not parallel or series connect an amplifier output with any other amplifier output Pairs of channels may be independently bridged channel pair A B and or channel pair C D The ...

Страница 11: ...ifications THD N 4 ohms 1kHz 1dB below max output power 0 08 0 008 0 008 THD N 4 ohms 20Hz to 20kHz 3dB below max output power 0 15 0 03 0 03 Gain Options dB 26 32 36 32 32 36 Sensitivity Options for maximum power dBu 16 10 6 3 5 7 5 3 5 Sensitivity Options for maximum power Volts 4 9 2 5 1 5 1 2 1 8 1 2 Frequency Response 20Hz to 20kHz dB 0 5 0 0 5 0 0 5 Input Impedance Active balanced k ohms Inp...

Страница 12: ...e from DAS Audio Group S L TECHNICAL SPECIFICATION LINE T Rated power handling input impedance 4 Ohms Output Impedance rated Frequency response Distor tion THD Weight each Dimensions mm 2U 500W 100V Standard 70 V Special 50 V Only 50Hz 16kHz 50Hz 16kHz Chassis only 500 tr W ansformer 20 0 Ohms 9 8 Ohms 5 0 Ohms 1dB 0 03 12 Kg 2 Kgs 8 88 x 482 x 428 mm When mounting the amplifier in a rack or enclo...

Страница 13: ...ndard To bring the 63 Hz roll off into circuit remove the 4 jumper links at hpf The response must be at least 3dB at 70 Hz and roll off at minimum 12dB per octave LINE TRANSFORMER LEAD OUTS 500W single 100V winding Primary Orange ve Black ve 4 ohms Secondary Yellow ve Grey ve 100V Blue centre tap for monitoring purposes only Note D 100 will give you 100V line out at the terminals D 20 will give yo...

Страница 14: ...2 504 564 668 936 Power Reduction Control Setting Per Channel Bridged Pair Maximum Power into 8 ohms W 1400 5300 2dB PRC 980 3700 4dB PRC 560 2100 6dB PRC 310 1175 Maximum Power into 4 ohms W 2800 7400 2dB PRC 1950 5160 4dB PRC 1110 2940 6dB PRC 620 1640 Maximum Power into 2 ohms W 3700 N A 2dB PRC 2580 N A 4dB PRC 1470 N A 6dB PRC 820 N A APPENDIX III No Sig l Quiescent Light Crest Factor of 7 8 ...

Страница 15: ...www 11sound com ...

Отзывы: