Terminals marked with the lightning symbol carry electrical current of sufficient magnitude to constitute risk of electric 

shock. Use only high quality cables with plugs pre-installed. All other installation or modification should be performed 

only by qualified personnel. This symbol, wherever it appears, alerts you to the presence of un-insulated dangerous 

voltage inside the enclosure - voltage that may be sufficient to constitute a risk of shock. This symbol, wherever it 

appears, alerts you to important operating and maintenance instructions in the accompanying literature.

Please read the manual. 

Caution: 

To reduce the risk of electric shock, do not remove the top cover (or the rear section). No user serviceable parts inside. 

Refer servicing to qualified personnel. 

Caution: To reduce the risk of fire or electric shock, do not expose this appliance to rain and moisture. The apparatus 

shall not be exposed to dripping or splashing liquids and no objects filled with liquids, such as vases, shall be placed on 

the apparatus. 

Caution: These service instructions are for use by qualified service personnel only. To reduce the risk of electric shock do 

not perform any servicing other than that contained in the operation instructions. Repairs have to be performed by 

qualified service personnel. 

1.

Read these instructions.

2.

Keep these instructions.

3.

Heed all warnings.

4.

Follow all instructions.

5.

Do not use this apparatus near water.

6.

Clean only with dry cloth.

7.

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce

heat.

9.

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with

one wider than the other.  A grounding-type plug has two blades and a third grounding prong. The wide blade or the

third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for

replacement of the obsolete outlet.

10.

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

11.

Use only attachments/accessories specified by the manufacturer.

12 .  

Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. 

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 

13.

Unplug this apparatus during lightning storms or when unused for long periods of time.

14.

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged

in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the

apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15.

The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.

16.

Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall

remain readily operable.

17.

Correct disposal of this product: The wheeled bin symbol indicates that this product must not be disposed of

with household waste. Please refer to the WEEE page of this manual.

SAFETY PRECAUTIONS

E11EVEN SOUND \ 

D series amplifiers 

User’s Manual

Содержание E11EVEN SOUND D Series

Страница 1: ...User s Manual D Series Amplifiers Before operating the device please read the Safety precautions section of this manual www 11sound com Deliver the Nightclub Sound Experience we all Deserve ...

Страница 2: ...ATION OF CONFORMITY WARRANTY INTRODUCTION UNPACKING THE UNIT INSTALLATION FRONT PANEL REAR PANEL CONNECTIONS SPECIFICATIONS APPENDIX I APPENDIX II APPENDIX III E11EVEN SOUND D series amplifiers User s Manual 3 4 5 6 7 8 11 12 13 9 11 14 ...

Страница 3: ...ch as radiators heat registers stoves or other apparatus that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult a...

Страница 4: ...4 DECLARATION OF CONFORMITY D10 D20 D100 E11EVEN SOUND D series amplifiers User s Manual ...

Страница 5: ...f the product All warranty repairs must be exclusively undertaken by the factory or any of its authorised service centers To claim a warranty repair do not open or intend to repair the product All the details related to the warranty such as extended warranties can be found in the SUPPORT section on our website www 11sound com E11EVEN SOUND D series amplifiers User s Manual ...

Страница 6: ... correct type and rating has been fitted Make sure power outlets conform to the power requirements listed on the back of the unit Damage caused by connecting to incorrect AC voltage is not covered by the warranty Mechanical Considerations To ensure that this equipment performs to specification it should be mounted in a suitable rack or enclosure When mounting the unit in a rack or enclosure ensure...

Страница 7: ...ls are bridged Bridge switches are on the rear panel 6 The D 10 and D 20 have Signal LEDs that are active from a minimum output level of approximately 10 Watts and are an indication only of signal presence The D 100 has Signal Meter and OCM indicators LED bar graphs show instantaneous level on each channel to indicate proximity to the limiter threshold Note that if the PRC system is in operation o...

Страница 8: ...facilitate easier wiring in bridged mode Channel B is wired pins 2 hot 2 cold Similarly channel C s output Speakon socket carries Channel D s output Check the table on the rear panel for details 3 D 10 D 20 Bridged Mono switch Depress this switch to run the amplifier in bridged mode Note that the output must be taken from channel A s output Speakon connector on pins 2 hot 1 cold D 100 Bridged mono...

Страница 9: ...ole NL2FC or 4 pole NL4FC connectors can be used Terminations are as follows HOT Pin 1 COLD Pin 1 Additionally Channel A Speakon connector carries Channel B output on Pins 2 2 to allow easy bi amping or bridged operation HOT Pin 2 COLD Pin 2 NOTE 1 Although the cold output terminals are nominally at 0V they should not be joined together otherwi se cross talk may be introduced 2 Because the current...

Страница 10: ...tputs to any other voltage source such as a battery mains source or power supply regardless of whether the amplifier is turned on or off Do not run the output of any amplifier channel back into another channel s input and do not parallel or series connect an amplifier output with any other amplifier output Pairs of channels may be independently bridged channel pair A B and or channel pair C D The ...

Страница 11: ...ifications THD N 4 ohms 1kHz 1dB below max output power 0 08 0 008 0 008 THD N 4 ohms 20Hz to 20kHz 3dB below max output power 0 15 0 03 0 03 Gain Options dB 26 32 36 32 32 36 Sensitivity Options for maximum power dBu 16 10 6 3 5 7 5 3 5 Sensitivity Options for maximum power Volts 4 9 2 5 1 5 1 2 1 8 1 2 Frequency Response 20Hz to 20kHz dB 0 5 0 0 5 0 0 5 Input Impedance Active balanced k ohms Inp...

Страница 12: ...e from DAS Audio Group S L TECHNICAL SPECIFICATION LINE T Rated power handling input impedance 4 Ohms Output Impedance rated Frequency response Distor tion THD Weight each Dimensions mm 2U 500W 100V Standard 70 V Special 50 V Only 50Hz 16kHz 50Hz 16kHz Chassis only 500 tr W ansformer 20 0 Ohms 9 8 Ohms 5 0 Ohms 1dB 0 03 12 Kg 2 Kgs 8 88 x 482 x 428 mm When mounting the amplifier in a rack or enclo...

Страница 13: ...ndard To bring the 63 Hz roll off into circuit remove the 4 jumper links at hpf The response must be at least 3dB at 70 Hz and roll off at minimum 12dB per octave LINE TRANSFORMER LEAD OUTS 500W single 100V winding Primary Orange ve Black ve 4 ohms Secondary Yellow ve Grey ve 100V Blue centre tap for monitoring purposes only Note D 100 will give you 100V line out at the terminals D 20 will give yo...

Страница 14: ...2 504 564 668 936 Power Reduction Control Setting Per Channel Bridged Pair Maximum Power into 8 ohms W 1400 5300 2dB PRC 980 3700 4dB PRC 560 2100 6dB PRC 310 1175 Maximum Power into 4 ohms W 2800 7400 2dB PRC 1950 5160 4dB PRC 1110 2940 6dB PRC 620 1640 Maximum Power into 2 ohms W 3700 N A 2dB PRC 2580 N A 4dB PRC 1470 N A 6dB PRC 820 N A APPENDIX III No Sig l Quiescent Light Crest Factor of 7 8 ...