33
INTEGRAL-M88 Manual
INTEGRAL
OSC control
OSC templates for mobile devices
Shown below the OSC standard DAS template for INTEGRAL-WP3
control panels. The template shall be upload into the mobile de-
vice using a computer as a server.
The template includes two main pages, one for gain, mute chang-
es and meter monitoring and the second one for preset recall.
The gain can be adjusted on both, input and output channels in
increments of 1.0dB. By the use of the “lock” button the user can
block the access to the WP3 panel. The default password for the
control panel Lock button is 0292. (Lock button only available
on WP3 templates).
On the preset recall page the user can have access to the first 10
global presets or memories stored internally by the user in the
Integral-MAxxxx or M88 units. A global preset change may af-
fect routing, gains, mutes, delays, EQs, Dante Outputs, Priority
settings etc, that is to say ALL the parameters.
Note: The user should use ALMA to configure all the settings and
storing all the global presets created.
It is highly recommended to use OCS in simple configurations were
one control panel controls a unique Integral device. (Although up
to five devices may be controlled with one WP3 panel).