![Darfon B09ULF Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/darfon/b09ulf/b09ulf_instruction-manual_3501272047.webp)
46 / 47
The equipment and packaging cannot be drenched, so it cannot be transported in the
open air.
6.3 System storage
Storage temperature
:
-20
℃~
25
℃
, 12 months
-20
℃~
45
℃
, 3 months
-20
℃~
60
℃
, 1 month
;
(The SOC before storage is kept in the range of 40% to 60 %.)
Storage humidity: 10%~80%RH
Storage rooms need to be kept ventilated.
The room is clean and dry, and it is protected from dust and moisture.
Room ground bearing >1200KG/
㎡
The storage time can be up to 6 months. It is recommended to charge and discharge the
system after the time is exceeded.
Storage room sunlight cannot be directly on the system.
The storage room should have a window for periodic inspection and record related
environmental data and storage time.